Versa 20 支架 光学支架 精密温控样品池支架

Versa 20

 

The Versa 20 is a standalone version of a versatile cuvette holder for absorbance measurements mounted on a simple base with a hole pattern for attachment to an optical breadboard. With optical ports on each side of the cuvette, use the Versa 20 for absorbance measurements or other experiments in which laser beams or other light is passed through the cuvette from one side to the other. The Versa 20 is ideal for work in the biological range of 0 °C to 110 °C, either to observe absorbance spectra at precisely maintained temperatures, or for temperature ramping, to observe how absorbance changes with temperature. To work at cold temperatures, purchase a Windowed Jacket, purge with dry gas and work down to -40 °C. For even more demanding work, purchase the extended temperature option and run the Versa 20 up to 150 °C or down to below -40 °C. The lowest effective temperature for working with the Versa 20 will depend on the conditions in the laboratory and how well the cuvette holder isolated from the ambient environment. To control the Versa 20, use the menu button on the TC 1/Single Temperature Controller, run Quantum Northwest’s program T-App, or write your own program for control.versa 20 是一个独立版本的多功能立方支架, 用于吸收测量, 安装在一个简单的底座上, 带有孔图案, 可连接到光学面包板上。在 cuvette 的每一侧都有光学端口时, 使用 versa 20 进行吸收测量或其他实验, 在这些实验中, 激光束或其他光从一个侧面传递到另一侧。versa 20 是在0°c 至110°c 的生物范围内工作的理想选择, 可以在精确保持温度下观察吸收光谱, 也可以观察温度的变化, 以观察吸收率如何随温度变化。要在低温下工作, 请购买风式夹克, 用干气清洗, 工作温度降低到-40°c。对于要求更高的工作, 请购买延长温度选项, 并在150°c 或-40°c 以下运行 versa 20。使用 versa 20 的最低有效温度将取决于实验室的条件以及与周围环境隔离的 cuvette 支架的情况。要控制 versa 20, 请使用 tc 半温度控制器上的菜单按钮, 运行昆腾西北的程序 t-app, 或编写自己的程序进行控制。

Product Features产品特点

Rapid, precise temperature control快速、精确的温度控制
Optional extended temperature range 可选的扩展温度范围
Windowed jacket available for temperature extremes 可用于极端温度的风装夹克
Variable speed magnetic stirring 变速磁搅拌
Dry gas purge for work at low temperature
低温工作用干气净化
Base and post for mounting on an optical breadboard 安装在光学面包板上的底座和立柱
Probe input for sample temperature 样品温度的探头输入
NIST-traceable temperature calibration nist 可追溯温度校准

技术参数

Number of cuvettes controlled:1
Typical use:Absorbance
Standard cuvette size (outside):12.5 mm x 12.5 mm
Optical ports per cuvette:2
Optical port dimensions:10 mm high x 10 mm wide
Cuvette z-height:8.5 or 15 mm for most models
Windowed jacket available:2 windows
Normal factory set temperature range:-40 °C to +105 °C
Temperature range easily achievable:-15 °C to +105 °C
Range with special techniques:-40 °C to +105 °C
Extended factory set temperature range:-55 °C to +150 °C
Extended temperature range achievable:-50 °C to +150 °C
Temperature precision:±0.02 °C
Temperature accuracy:Better than ±0.15 °C from 0 ⁰C to +80 ⁰C
Accuracy greater range:Better than ±0.3 ⁰C from ‐20 ⁰C to +110 ⁰C
Temperature reproducibility:Better than ±0.07 °C
Thermistor probes accepted:Series 400 or Series 500
Magnetic stirring motor type:Stepper
Magnetic stirring speed range:1-2500 rpm
Default stirring speed:1200 rpm
Stirring speed best performance:60-1800 rpm

Basic Package
Versa 20 – Temperature-controlled cuvette holder (standard z-height = 15 mm with cuvette lifter)
TC 1/Single – Temperature Controller
Baseplate for mounting on an optical breadboard
BATH 10 – Circulator
NIST-traceable calibration and performance data
Accessories – Magnetic stir bar, tubing, cables and opaque cap

Accessories
T-App
Water Circulators
Cuvette Adapters
Thermistor Probes
Extended Temperature
WJ-20

 