美国 Monarch Instrument ROLS——远程光学 LED 传感器

美国 Monarch Instrument

ROLS——远程光学 LED 传感器

ROLS Remote Optical Laser Sensor is versatile and able to work over long distances up to 25 feet - Monarch Instrument

ROLS Remote Optical Laser Sensor is versatile and able to work over long distances up to 25 feet - Monarch Instrument

ROLS Remote Optical Laser Sensor is versatile and able to work over long distances up to 25 feet - Monarch Instrument

ROLS Remote Optical Laser Sensor is versatile and able to work over long distances up to 25 feet - Monarch Instrument

描述

1-250,000 RPM。用途极其广泛,能够长距离工作(最远 25 英尺)。ROLS-W(镀锡线端接)和 ROLS-P(1/8 英寸电话插头端接)是螺纹不锈钢远程光学传感器,配有可见的红色激光光源。所有这些传感器都配有目标绿色 LED 指示灯。 

型号 ROLS-P:远程光学激光传感器,配有 8 英尺电缆、1/8 英寸 [3.5 毫米] 电话插头连接器、带防松螺母的安装支架和 12 英寸 T-5反光 

型号 ROLS-P-25: 远程光学激光传感器,配有 25 英尺电缆、1/8 英寸 [3.5 毫米] 电话插头连接器、带防松螺母的安装支架和 12 英寸 T-5 反光带

型号 ROLS-W:远程光学激光传感器,配有 8 英尺电缆、3 根镀锡导线、带防松螺母的安装支架和 12 英寸 T-5 反光带

型号 ROLS24-W:远程光学激光传感器,配备 24 V 直流输入电源、8 英尺电缆、3 根镀锡导线、带防松螺母的安装支架和 12 英寸 T-5 反光带

型号 ROLS24-W-25: 远程光学激光传感器,配备 24 V 直流输入电源、25 英尺电缆、3 根镀锡导线、带防松螺母的安装支架和 12 英寸 T-5 反光带

 

参数

W= tinned wire leads, P= 1/8″ [3.5 mm] stereo phone plug termination).

MODELROLS-P
ROLS-W
Specifications*

 CE marked

Speed Range1-250,000 RPM
IlluminationVisible Red Laser, Class 2 (per IEC 60825-1:2014)
    ClassificationThis product complies with IEC60825-1 Ed. 3 and 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50 of June 2007
    Max Laser Output1 mW max
    Pulse DurationContinuous
    Laser Wavelength650nm (visible red)
    Beam Divergence< 18 mrad
    Beam Diameter4 x 7 mm typical at 2 m
    Laser Diode Life8,000 operating hours MTBF (1-year warranty)
On-Target IndicatorGreen LED on the wire end cap
Operating RangeUp to 25 ft. [7.6 m] and 60 degrees offset from the target
Power Requirement ROLS: 3.3 – 15 V dc, 0.4W max

ROLS24-W: 24 V dc ±10%, 0.4W max

NOTE: 24 V dc power input option available see ordering information.

Output ROLS: Open collector with an internal pull-up resistor to supply voltage; positive pulse when target present; Output Voltage = Supply Voltage

ROLS24-W: Open collector with an internal pull-up resistor (5600 ohms) to supply voltage minus ~5V; positive pulse when a target is present

Optional Outputs Available – Open Collector or TTL pulse (3.3 V dc), Negative pulse (contact factory)

Operating Temp14 °F to 158 °F (-10 °C to 70 °C)
HumidityMaximum relative humidity 80% for temperature up to 88 °F (31 °C)
decreasing linearly to 50% relative humidity 104 °F (40 °C)
Connection3.5 mm [1/8 inch] male stereo plug (ROLS-P);
Tinned wires (ROLS-W)
Material303 stainless steel supplied with two M18 jam nuts and mounting bracket
LensAcrylic plastic
DimensionsThreaded tube 3.12 in. x 0.71 in. diameter [18 x 79.4 mm] long