Vortex Probe VA40 … ZG7探头

Vortex probe VA40 with sensor head diagonal dimension 40 mm and transducer UVA integrated in the connection housing. Probe material: stainless steel. Working temperature range up to +100 or +180 °C.
Suitable for fixed measuring of actual flow velocity v [m/s] and actual flow rate V/t [m³/h] in clean as well as condensate and particulate-laden gases.

Signal evaluation with integrated transducer UVA.

 

according to drawing ZG7
Measuring range:0.5 … 40 m/s
Working pressure range:up to 3 bar / 300 kPa overpressure
Working temperature range:-20 … +100 / +180 °C
SIL approval:SIL2
Medium:gases
Displayed meaurement categories:flow velocity, flow rate, volume
IP  protection:IP65 (connection housing)
Ex protection:ATEX category 3G and 3D (zone 2 and 22) (optional)
Sensor outputs:analog output 4-20 mA, limit value, quantity pulse, RS232 interface