﻿{"id":81,"date":"2018-08-14T14:09:46","date_gmt":"2018-08-14T06:09:46","guid":{"rendered":"https:\/\/www.bihec.com\/tyne\/?p=81"},"modified":"2018-08-14T14:09:46","modified_gmt":"2018-08-14T06:09:46","slug":"7044-response-time-monitor-%e5%93%8d%e5%ba%94%e6%97%b6%e9%97%b4%e7%9b%91%e8%a7%86%e5%99%a8","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/tyne\/7044-response-time-monitor-%e5%93%8d%e5%ba%94%e6%97%b6%e9%97%b4%e7%9b%91%e8%a7%86%e5%99%a8\/","title":{"rendered":"7044 Response Time Monitor \u54cd\u5e94\u65f6\u95f4\u76d1\u89c6\u5668"},"content":{"rendered":"<p><img decoding=\"async\" loading=\"lazy\" class=\"\" src=\"http:\/\/www.tyne-engineering.com\/images\/7044-003-GAMM.jpg\" width=\"411\" height=\"308\" \/><\/p>\n<div class=\"section\">\n<p>Tyne Engineering&#8217;s Response Time Monitor can be used for critical or safety-related actuator response monitoring or as a delay-on timer. An example application is for testing the response time of the vent panel opening in the Power House Emergency Venting System in Nuclear Power Plants.<\/p>\n<div id=\"\">Tyne\u7684\u54cd\u5e94\u65f6\u95f4\u76d1\u6d4b\u53ef\u7528\u4e8e\u5173\u952e\u6216\u4e0e\u5b89\u5168\u6709\u5173\u7684\u6267\u884c\u5668\u54cd\u5e94\u76d1\u89c6\u6216\u4f5c\u4e3a\u5ef6\u8fdf\u8ba1\u65f6\u5668\u3002\u5b9e\u4f8b\u5e94\u7528\u4e8e\u6838\u7535\u7ad9\u5e94\u6025\u6cc4\u653e\u7cfb\u7edf\u4e2d\u7684\u901a\u98ce\u677f\u5f00\u53e3\u54cd\u5e94\u65f6\u95f4\u7684\u6d4b\u8bd5\u3002\u7279\u5f81<\/p>\n<p>6\u5404\u81ea\u7684\u6e20\u9053<br \/>\n\u6210\u719f\u7684\u786c\u4ef6\u95e8\u903b\u8f91\u8bbe\u8ba1, \u4e0d\u6d89\u53ca\u53ef\u7f16\u7a0b\u8bbe\u5907, \u4e5f\u6ca1\u6709\u8f6f\u4ef6\u3002<br \/>\n\u6bcf6\u4e2a\u54cd\u5e94\u65f6\u95f4\u76d1\u89c6\u5668\u90fd\u4ee5\u6570\u5b57\u5f62\u5f0f\u663e\u793a\u3002\u6bcf\u4e2a\u901a\u9053\u90fd\u6709\u7528\u4e8e\u8fd0\u884c\u65f6\u95f4\u548c\u72b6\u6001\u6307\u793a\u706f\u6307\u793a\u5668\u7684\u6570\u5b57\u663e\u793a\u3002<br \/>\n\u5177\u6709\u72b6\u6001\u6307\u793a\u5668\u7684\u5197\u4f59\u7535\u6e90\u3002<br \/>\n\u53ef\u901a\u8fc7\u6570\u5b57 BCD \u5f00\u5173\u8bbe\u7f6e\u62a5\u8b66\u65f6\u95f4\u3002<\/p>\n<h2 class=\"underlined_10\">Specifications<\/h2>\n<div class=\"section\">\n<table class=\"ForrestTable\" cellspacing=\"1\" cellpadding=\"4\">\n<tbody>\n<tr>\n<td>Timing Resolution<\/td>\n<td>0.01S (10mS)<\/td>\n<\/tr>\n<tr>\n<td>Timing Accuracy<\/td>\n<td>0.01S(10mS)<\/td>\n<\/tr>\n<tr>\n<td>EMC Qualification<\/td>\n<td>IEC 61000-4-2, Electrical Discharge Requirements<\/p>\n<p>IEC 61000-4-3, Radiated Electromagnetic Field Requirement<\/p>\n<p>IEC 61000-4-4, Electrical Fast Transient\/Burst Requirements<\/p>\n<p>IEC 61000-4-5, Surge Withstand<\/p>\n<p>IEC 61000-4-6, Conducted RF Immunity<\/p>\n<p>IEC 61000-4-8, Magnetic Field Immunity Test<\/p>\n<p>IEC 61000-4-11, Voltage Dip, Dropouts, interrupts and voltage<\/td>\n<\/tr>\n<tr>\n<td>Number of Channels:<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>Panel Mount, Overall dimension: 7\u201d height X 13.5\u201d width X 10\u201d depth<\/td>\n<\/tr>\n<tr>\n<td>Control Contacts (Alarm)<\/td>\n<td>Dry NO contact, Contact rating 0.5\/48VDC.<\/td>\n<\/tr>\n<tr>\n<td>Input Contacts (Start\/Stop\/Reset)<\/td>\n<td>Dry contacts, Contact Rating: 0.1A @12VDC.<\/td>\n<\/tr>\n<tr>\n<td>Power Supply<\/td>\n<td>120VAC \u00b1 10%, 60Hz \u00b1 2Hz.<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption<\/td>\n<td>&lt;24VA.<\/td>\n<\/tr>\n<tr>\n<td>Timing aging<\/td>\n<td>\u00b10.05mS per year in 10-second range (\u00b15ppm\/Year Frequency aging Crystal used for timing)<\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td>0-99.99S<\/td>\n<\/tr>\n<tr>\n<td>Alarm Setting<\/td>\n<td>1-99S, with 1 Second step.<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td>10-50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Operating Humidity<\/td>\n<td>Up to 90%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<br><div class=\"tagcloud\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Tyne Engineering&#8217;s Response Time Monitor can be used for critical or safety-related  <\/p>\n","protected":false},"author":18,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/posts\/81"}],"collection":[{"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/comments?post=81"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/posts\/81\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/media?parent=81"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/categories?post=81"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/tyne\/wp-json\/wp\/v2\/tags?post=81"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}