﻿{"id":74,"date":"2018-07-29T09:40:55","date_gmt":"2018-07-29T01:40:55","guid":{"rendered":"https:\/\/www.bihec.com\/systherms\/?p=74"},"modified":"2019-07-09T17:01:02","modified_gmt":"2019-07-09T09:01:02","slug":"vws%e7%9c%9f%e7%a9%ba%e7%83%ad%e5%a4%84%e7%90%86%e7%82%89","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/systherms\/vws%e7%9c%9f%e7%a9%ba%e7%83%ad%e5%a4%84%e7%90%86%e7%82%89\/","title":{"rendered":"VWS\u771f\u7a7a\u70ed\u5904\u7406\u7089"},"content":{"rendered":"<p>The furnace with bottom loading (bottom loader) is commonly used for round and heavy components. In principle, this type of furnace is a vertical <a href=\"https:\/\/www.bihec.com\/systherms\/tag\/vwc\/\" title=\"View all posts in VWC\" target=\"_blank\">VWC<\/a> in which the load is positioned on the furnace bottom which can be lowered. The lowered furnace bottom can be driven by motor so that the batch can be loaded and unloaded by a hall crane.<\/p>\n<p>Our vacuum furnace type <a href=\"https:\/\/www.bihec.com\/systherms\/tag\/vws\/\" title=\"View all posts in VWS\" target=\"_blank\">VWS<\/a> can also be used for a multitude of applications as for example low pressure carburizing, hardening, tempering, annealing and brazing.<\/p>\n<p>The heat exchanger is either mounted above the heating chamber or in order to minimize the height in a separate housing beside the furnace vessel.<\/p>\n<p>&nbsp;<\/p>\n<h3>Advantages:<\/h3>\n<ul>\n<li>optimum treatment of large rotation-symmetric components<\/li>\n<li>homogenous quenching with optional loading table rotation<\/li>\n<li>space-saving design possible with external heat exchanger<\/li>\n<li>high batch weights possible<\/li>\n<li>heating chamber in metallic design is possible<\/li>\n<li>uniform treatment results, even under most difficult conditions<\/li>\n<li>highest\u00a0temperature uniformity during heating and quenching<\/li>\n<li>heating and quenching characteristics according to your requirements<\/li>\n<li>complies with all current aviation standards (<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/ams-2750-e\/\" title=\"View all posts in AMS 2750 E\" target=\"_blank\">AMS 2750 E<\/a>, <a href=\"https:\/\/www.bihec.com\/systherms\/tag\/nadcap\/\" title=\"View all posts in NADCAP\" target=\"_blank\">NADCAP<\/a>, etc.<span lang=\"EN-GB\">)<\/span><\/li>\n<li>\n<div align=\"justify\"><span lang=\"DE\">simple and secure control via touch screen<\/span><\/div>\n<\/li>\n<li><span lang=\"DE\">proper control system &#8220;hestia&#8221;<\/span><\/li>\n<li>\n<div align=\"justify\"><span lang=\"DE\">different high vacuum options: oil diffusion pumps, turbo molecular pumps, cryo pumps<\/span><\/div>\n<\/li>\n<\/ul>\n<h3>Standard sizes:<\/h3>\n<p><strong>Type\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0useable dimensions<\/strong><\/p>\n<p><strong>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/strong>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<strong> (\u00d8xH in mm) <\/strong><br \/>\nVWS 1010\u00a0\u00a0\u00a0 1000 x 1000<br \/>\nVWS 1515\u00a0\u00a0\u00a0 1500 x 1500<br \/>\nVWS 2020\u00a0\u00a0\u00a0 2000 x 2000<\/p>\n<p>Other sizes and technical details are available on request.<\/p>\n<br><div class=\"tagcloud\"><a href=\"https:\/\/www.bihec.com\/systherms\/tag\/systherms\/\" class=\"tag-cloud-link tag-link-0 tag-link-position-1\" style=\"font-size: 22pt;\" aria-label=\"Systherms (48\u4e2a\u9879\u76ee)\">Systherms<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/vws\/\" class=\"tag-cloud-link tag-link-1 tag-link-position-2\" style=\"font-size: 8pt;\" aria-label=\"VWS (3\u4e2a\u9879\u76ee)\">VWS<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e4%bd%8e%e5%8e%8b%e6%b8%97%e7%a2%b3\/\" class=\"tag-cloud-link tag-link-2 tag-link-position-3\" style=\"font-size: 18.660550458716pt;\" aria-label=\"\u4f4e\u538b\u6e17\u78b3 (26\u4e2a\u9879\u76ee)\">\u4f4e\u538b\u6e17\u78b3<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e5%9b%9e%e7%81%ab\/\" class=\"tag-cloud-link tag-link-3 tag-link-position-4\" style=\"font-size: 19.94495412844pt;\" aria-label=\"\u56de\u706b (33\u4e2a\u9879\u76ee)\">\u56de\u706b<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e7%84%8a%e6%8e%a5\/\" class=\"tag-cloud-link tag-link-4 tag-link-position-5\" style=\"font-size: 17.247706422018pt;\" aria-label=\"\u710a\u63a5 (20\u4e2a\u9879\u76ee)\">\u710a\u63a5<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e7%9c%9f%e7%a9%ba%e6%b7%ac%e7%81%ab%e7%82%89\/\" class=\"tag-cloud-link tag-link-5 tag-link-position-6\" style=\"font-size: 17.504587155963pt;\" aria-label=\"\u771f\u7a7a\u6dec\u706b\u7089 (21\u4e2a\u9879\u76ee)\">\u771f\u7a7a\u6dec\u706b\u7089<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e7%9c%9f%e7%a9%ba%e7%82%89\/\" class=\"tag-cloud-link tag-link-6 tag-link-position-7\" style=\"font-size: 19.688073394495pt;\" aria-label=\"\u771f\u7a7a\u7089 (31\u4e2a\u9879\u76ee)\">\u771f\u7a7a\u7089<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e7%9c%9f%e7%a9%ba%e7%83%ad%e5%a4%84%e7%90%86%e7%82%89\/\" class=\"tag-cloud-link tag-link-7 tag-link-position-8\" style=\"font-size: 19.43119266055pt;\" aria-label=\"\u771f\u7a7a\u70ed\u5904\u7406\u7089 (30\u4e2a\u9879\u76ee)\">\u771f\u7a7a\u70ed\u5904\u7406\u7089<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e7%a1%ac%e5%8c%96\/\" class=\"tag-cloud-link tag-link-8 tag-link-position-9\" style=\"font-size: 16.091743119266pt;\" aria-label=\"\u786c\u5316 (16\u4e2a\u9879\u76ee)\">\u786c\u5316<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e7%ac%a6%e5%90%88%e8%88%aa%e7%a9%ba%e6%a0%87%e5%87%86\/\" class=\"tag-cloud-link tag-link-9 tag-link-position-10\" style=\"font-size: 16.733944954128pt;\" aria-label=\"\u7b26\u5408\u822a\u7a7a\u6807\u51c6 (18\u4e2a\u9879\u76ee)\">\u7b26\u5408\u822a\u7a7a\u6807\u51c6<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e9%80%80%e7%81%ab\/\" class=\"tag-cloud-link tag-link-10 tag-link-position-11\" style=\"font-size: 18.660550458716pt;\" aria-label=\"\u9000\u706b (26\u4e2a\u9879\u76ee)\">\u9000\u706b<\/a>\n<a href=\"https:\/\/www.bihec.com\/systherms\/tag\/%e9%80%82%e7%94%a8%e9%87%8d%e5%9e%8b%e6%88%96%e8%b6%85%e9%95%bf%e9%83%a8%e4%bb%b6%e7%9a%84%e7%83%ad%e5%a4%84%e7%90%86\/\" class=\"tag-cloud-link tag-link-11 tag-link-position-12\" style=\"font-size: 16.477064220183pt;\" aria-label=\"\u9002\u7528\u91cd\u578b\u6216\u8d85\u957f\u90e8\u4ef6\u7684\u70ed\u5904\u7406 (17\u4e2a\u9879\u76ee)\">\u9002\u7528\u91cd\u578b\u6216\u8d85\u957f\u90e8\u4ef6\u7684\u70ed\u5904\u7406<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>The furnace with bottom loading (bottom loader) is commonly used for round and heavy compo <\/p>\n","protected":false},"author":1,"featured_media":75,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[5],"tags":[7,26,9,11,25,18,17,8,24,14,12,23],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/posts\/74"}],"collection":[{"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/comments?post=74"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/posts\/74\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/media\/75"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/media?parent=74"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/categories?post=74"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/systherms\/wp-json\/wp\/v2\/tags?post=74"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}