Luma 40/Duetta 支架 光学支架 精密温控样品池支架

Luma 40/Duetta

Peltier-based temperature-controlled cuvette holder for Horiba’s Duetta Fluorescence and Absorbance Spectrometer  基于 peltier 的温度控制 cuvette 支架, 用于霍里巴的杜达荧光和吸收光谱

The Luma 40/Duetta is a temperature-controlled cuvette holder for use in a Horiba’s Duetta Fluorescence and Absorbance Spectrometer. Use the Luma 40/Duetta for normal temperature ranges of -15 °C to +105 °C. Add a Windowed Jacket, purge with dry gas and run the temperature down to at least -40 °C. Purchase the extended temperature option and extend the range up to +150 °C or down to about -50 °C. Fluorescence is sensitive to temperature and reliable measurements require the precise temperature control of the Luma 40/Duetta. Horiba provides sophisticated, fully integrated control for the Luma 40/Duetta. luma 40/duetta 是一个温度控制的 cuvette 持有人, 用于霍利巴的杜塔荧光和吸收光谱仪。在-15°c 至 + 105°c 的常温范围内使用 luma 40/duetta。加入一个风夹克, 用干气清洗, 并将温度降至-40°c。购买扩展温度选项, 并将范围扩展到 + 150°c 或向下至-50°c 左右。荧光对温度敏感, 可靠的测量需要对 luma 40 _ duetta 进行精确的温度控制。

Product Features产品特点

Four optical ports 四个光学端口
Rapid, precise temperature control 快速、精确的温度控制
Optional extended temperature range可选的扩展温度范围
Windowed jacket available for temperature extremes可用于极端温度的风装夹克
Variable speed magnetic stirring变速磁搅拌
Dry gas purge for work at low temperature低温工作用干气净化
Mounted on a Duetta tray for easy insertion安装在 duetta 托盘上, 便于插入
Probe input for sample temperature样品温度的探头输入
NIST-traceable temperature calibrationnist 可追溯温度校准

Technical Specifications

Number of cuvettes controlled:1
Typical use:Fluorescence
Standard cuvette size (outside):12.5 mm x 12.5 mm
Optical ports per cuvette:4
Optical port dimensions:12 mm high x 10 mm wide
Built-in optical slit holders:4 per cuvette
Cuvette z-height:8.5 or 15 mm for most models
Windowed jacket available:2, 3 or 4 windows
Normal factory set temperature range:-40 °C to +105 °C
Temperature range easily achievable:-15 °C to +105 °C
Range with special techniques:-40 °C to +105 °C
Extended factory set temperature range:-55 °C to +150 °C
Extended temperature range achievable:-50 °C to +150 °C
Temperature precision:±0.02 °C
Temperature accuracy:Better than ±0.15 °C from 0 ⁰C to +80 ⁰C
Accuracy greater range:Better than ±0.3 ⁰C from ‐20 ⁰C to +110 ⁰C
Temperature reproducibility:Better than ±0.07 °C
Thermistor probes accepted:Series 400 or Series 500
Magnetic stirring motor type:Stepper
Magnetic stirring speed range:1-2500 rpm
Default stirring speed:1200 rpm
Stirring speed best performance:60-1800 rpm

Basic Package
Luma 40 – Temperature-controlled cuvette holder (standard z-height = 15 mm)
Duetta accessory tray
TC 1/Single – Temperature Controller
KOOL 440 – Circulator
NIST-traceable calibration and performance data
Accessories – Magnetic stir bar, tubing, cables, optical slits and opaque cap

 