﻿{"id":1510208,"date":"2014-10-14T17:09:53","date_gmt":"2014-10-14T09:09:53","guid":{"rendered":"https:\/\/www.bihec.com\/?p=1426"},"modified":"2019-03-05T15:48:52","modified_gmt":"2019-03-05T07:48:52","slug":"lt-industries-inc%e5%85%ac%e5%8f%b8-parafuel-nir-biodiesel-analyzer-2","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/lt-industries\/lt-industries-inc%e5%85%ac%e5%8f%b8-parafuel-nir-biodiesel-analyzer-2\/","title":{"rendered":"ParaFuel&#x2122; NIR Biodiesel Analyzer"},"content":{"rendered":"<p>ParaFuel&#x2122; systems from LT Industries\u00a0are small, rugged analyzers designed for\u00a0use in biodiesel Plants &amp; laboratories.\u00a0Whatever the analytical need \u2013 Finished\u00a0product qualification, In-Process readings,\u00a0or incoming product properties &#8212; the\u00a0ParaFuel&#x2122; system can do the job. You\u00a0can expect low cost, fast results, and low\u00a0operator training loads from every\u00a0ParaFuel&#x2122; system.<\/p>\n<p>ParaFuel\u2019s full networking capability allows\u00a0data to be accessed wherever needed. OpCon-II\u00a0user interface provides customized screens,\u00a0result reporting, and data-logging. LTBus\u00a0software allows the system to interface with plant\u00a0DCS, PLC, or other computer systems using\u00a0Modbus, 4-20 mA, and other protocols.<\/p>\n<p>Easy to use, easy to own<br \/>\nMake fussy sampling procedures a thing of the\u00a0past. Simply dip the probe into a sample and hit\u00a0\u201cEnter\u201d on the controlling computer. The\u00a0ParaFuel provides your analytical results in\u00a0seconds.<\/p>\n<p>Available Options:<\/p>\n<p>\u2022 On-Line Integration \u2013 With sampling points<\/p>\n<p>directly in the process get real time\u00a0automated results. Use them to control your\u00a0process to balance other inputs, insure\u00a0complete reactions, and increase yield of\u00a0ASTM approved product.<\/p>\n<p>Analyzer Specifications:<\/p>\n<p>The ParafuelTM analyzer equipped with a Multiplexer, fiber optic<br \/>\ncable, and probe was used to scan Biodiesel blends and B-100<br \/>\ndirectly off the process.<br \/>\nThe measurements shown are Glycerin (Mono-, Di-, Tri-, and Total)<br \/>\nand the ratio of Biodiesel\/Diesel<br \/>\nfrom 1 to 20%. Blended product<br \/>\nincluded Animal Fat, Chicken Fat,<br \/>\nVegetable Fat, and Used Recycled<br \/>\nGrease as FAME sources. This<br \/>\nextreme range of variables indicates<br \/>\nthe robustness of the technique.<br \/>\nThe measurements shown are only<br \/>\na sampling of what the ParaFuelTM<br \/>\ncan bring to your lab.<\/p>\n<p>Reliability: Designed for twenty-four hour operations without shut-down.<br \/>\nSpectral range: 1200 \u2013 2400 nm (other ranges available from 400 \u2013 2400 nm)<br \/>\nScanning speed: 5 scans per second<br \/>\nSpectral addition: Scans may be added under computer control<br \/>\nMeasurement modes: Reflectance, Transmittance, Transflectance<br \/>\nData interval: 1 nm (1200 points over the spectral range)<br \/>\nBandwidth: 10 nm<br \/>\nPhotometric range: 5 Absorbance Units<br \/>\nWavelength repeatability: 0.01 nm<br \/>\nStray light: 0.1% or better<br \/>\nLight geometry: Optimized for minimum specular reflectance and maximal S\/N<br \/>\nAuxiliary port: Computer controlled for alternative sampling<br \/>\nPossible signal output: Multiple 4-20 mA, multiple voltages, MODBUS, and more<br \/>\nPower: 120V, 3.5 Amp, 60Hz or 220V, 1.8 Amp, 50 Hz<br \/>\nPower transients: Filtered<br \/>\nDimensions: 12\u201d x 15\u201c x 13\u201c (HWD), 30.5 cm x 39.7 cm x 34.9 cm (HWD)<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<br><div class=\"tagcloud\"><\/div>","protected":false},"excerpt":{"rendered":"<p>ParaFuel&#x2122; systems from LT Industries\u00a0are small, rugged analyzers designed for\u00a0use i <\/p>\n","protected":false},"author":1,"featured_media":70,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[12],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/posts\/1510208"}],"collection":[{"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/comments?post=1510208"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/posts\/1510208\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/media\/70"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/media?parent=1510208"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/categories?post=1510208"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/lt-industries\/wp-json\/wp\/v2\/tags?post=1510208"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}