﻿{"id":148,"date":"2018-07-25T20:44:30","date_gmt":"2018-07-25T12:44:30","guid":{"rendered":"https:\/\/www.bihec.com\/kimballphysics\/?p=148"},"modified":"2019-06-17T23:05:30","modified_gmt":"2019-06-17T15:05:30","slug":"%e7%be%8e%e5%9b%bdkimball-physics%e5%85%ac%e5%8f%b8efg-7-egps-2017%e7%94%b5%e5%ad%90%e6%9e%aa","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/kimballphysics\/%e7%be%8e%e5%9b%bdkimball-physics%e5%85%ac%e5%8f%b8efg-7-egps-2017%e7%94%b5%e5%ad%90%e6%9e%aa\/","title":{"rendered":"EFG-7 \/ EGPS-2017\u7535\u5b50\u67aa"},"content":{"rendered":"<div class=\"product-name\" style=\"font-size: 14px; font-weight: bold; line-height: 14px; color: rgb(68, 68, 68); margin: 0px 0px 10px; font-family: Arial, Helvetica, sans-serif;\">\n<h5 style=\"float: none; font-size: 12px; margin: 0px; color: rgb(120, 122, 129) !important;\">\n\t\tElectron Gun System: 100 eV to 5000 eV<br \/>\n\t<\/h5>\n<\/div>\n<div class=\"short-description std\" style=\"line-height: 17px; color: rgb(85, 85, 85); font-family: Arial, Helvetica, sans-serif; padding: 10px 0px 0px;\">\n<h3 style=\"float: none; color: rgb(120, 122, 129); font-size: 12px; font-weight: bold; line-height: normal; margin: 0px 0px 5px;\">\n\t\tQuick Overview<br \/>\n\t<\/h3>\n<p>\n\t\tNarrow-angle or uniform wide-angle beam<\/p>\n<p>\t\t<strong>Energy Range:<\/strong>&nbsp;100 eV to 5000 eV<br \/>\n\t\t<strong>Beam current \/ Spot sizes:<\/strong><br \/>\n\t\tStandard: 10 nA to 100 &micro;A \/ 1 mm to 100 mm<br \/>\n\t\tHigh Current: 10 nA to 1 mA \/ 3 mm to 100 mm<br \/>\n\t\t<strong>Mounting:<\/strong>&nbsp;2&frac34;CF, demountable option<br \/>\n\t\t<strong>Features\/Options:<\/strong>&nbsp;Flood Beam or Narrow-Angle Beam, Electrostatic Focusing, Deflection, Rastering, Pulsing\n\t<\/p>\n<p>\n\t\t&nbsp;\n\t<\/p>\n<p>\n\t\tFOR USE IN:<br \/>\n\t\tSurface Physics Studies<br \/>\n\t\tVacuum Physics Experiments<br \/>\n\t\tCharge Neutralization&nbsp;<br \/>\n\t\tElectron Desorption&nbsp;<br \/>\n\t\tSurface Scrubbing<br \/>\n\t\tPhospher Testing<br \/>\n\t\tIonization Experiments<br \/>\n\t\tSemiconductor Processing\n\t<\/p>\n<p>\n\t\tFEATURES \/ OPTIONS:<br \/>\n\t\tWidely Controllable Parameters<br \/>\n\t\tFlood Beams or Narrow Angle Beam<br \/>\n\t\tElectrostatic Focusing<br \/>\n\t\tDeflection, Rastering, Pulsing<br \/>\n\t\tDemountable Gun<br \/>\n\t\tComputer \/ Remote Control<br \/>\n\t\t&nbsp;\n\t<\/p>\n<p>\n\t\t5 keV MODEL <a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/efg-7\/\" title=\"View all posts in EFG-7\" target=\"_blank\">EFG-7<\/a> ELECTRON GUN SPECIFICATIONS\uff1a<br \/>\n\t\tBEAM ENERGY \uff1a100 eV to 5 keV (Independently adjustable)<br \/>\n\t\tBEAM CURRENT \uff1aStandard: 1 nA to 100 &mu;A (Independently adjustable)<br \/>\n\t\tENERGY SPREAD\uff1aApprox. cathode thermal spread, calculated&nbsp;Ta &#8211; 0.5eV <a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/y2o3\/\" title=\"View all posts in Y2O3\" target=\"_blank\">Y2O3<\/a> &#8211; 0.4eV BaO &#8211; 0.3eV<br \/>\n\t\tSPOT SIZE \uff1aStandard: 1 mm to 100 mm (Independently adjustable)<br \/>\n\t\tWORKING DISTANCE\uff1aVariable: 25 mm to 200 mm&nbsp;<br \/>\n\t\tBEAM DEFLECTION \uff1aOptional: 4 pole electrostatic: &plusmn; 3&deg; at 5 keV; scales&nbsp;larger at lower energies<br \/>\n\t\tPULSE CAPABILITY(using appropriate&nbsp;pulse generator,not included)\uff1a<br \/>\n\t\tOptional Capacitive Pulse Junction Box: pulse width&nbsp;20 ns to 100 &mu;s , rise\/ fall 10 ns, 50 &Omega; impedance, 1 W&nbsp;standard (higher power available)<br \/>\n\t\tOptional Dual Grid Power Supply: pulse width 2 &mu;s to&nbsp;DC, rise\/ fall 500 ns, rep rates to 5kHz (TTL required)<br \/>\n\t\tBEAM UNIFORMITY \uff1aGaussian or uniform. depending on operation<br \/>\n\t\tFIRING UNIT\uff1a<br \/>\n\t\tCustomer-replaceable Firing Unit includes&nbsp;precision-aligned cathode and Wehnelt (G-1) assembly&nbsp;and anode, with insulators and connectors<br \/>\n\t\tCATHODE TYPES\uff1a<br \/>\n\t\tStandard: <a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/tantalum\/\" title=\"View all posts in Tantalum\" target=\"_blank\">Tantalum<\/a> disc<br \/>\n\t\tOptional: Barium oxide (BaO) or Yttrium oxide (Y2O3)&nbsp;With the exception of Barium oxide, cathodes not&nbsp;harmed by repeated exposure to atmospheric gases&nbsp;while cold<br \/>\n\t\tMOUNTING\uff1a<br \/>\n\t\tStandard: Flange Adaptor with a 2&frac34; inch CF (no deflect)<br \/>\n\t\tOptional: Flange Multiplexer with a 2&frac34; inch rotatable&nbsp;CF,including both tapped and clear mounting holes<br \/>\n\t\tOptional: Demountable (Unmounted \/ Mounted) with&nbsp;a Flange Multiplexer with a 2&frac34; inch rotatable CF<br \/>\n\t\tBEAM ALIGNMENT \uff1aOptional: Mechanical alignment with &plusmn; 2&deg; Port Aligner<br \/>\n\t\tINSERTION LENGTH\uff1a<br \/>\n\t\tStandard: 160 mm, Range: 120 mm to 180 mm.&nbsp;<br \/>\n\t\tDemounted gun :Gun length with pins 135 mm standard&nbsp;Custom lengths available. Gun manufactured at&nbsp;standard length unless otherwise specified at time of&nbsp;order.<br \/>\n\t\tGUN DIAMETER\uff1a<br \/>\n\t\t25.4 mm at the gun flange, necks down to 19.1 mm at100 mm from the flange<br \/>\n\t\tFEEDTHROUGHS \uff1aMulti-pin brazed ceramic, threaded stainless steel shell<br \/>\n\t\tCABLES \/CONNECTORS<br \/>\n\t\tMulti-conductor high voltage fully ground-shielded cable,coaxial grid cable, low voltage deflection cable, with&nbsp;mating aluminum shell connectors, to connect gun and&nbsp;power supply.\n\t<\/p>\n<p>\n\t\tStandard lengths: 3 m Optional: 5 m&nbsp;MAXIMUM BAKEOUT 350&deg;C with cables removed\n\t<\/p>\n<p>\n\t\t&nbsp;\n\t<\/p>\n<p>\n\t\t<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egps-2017\/\" title=\"View all posts in EGPS-2017\" target=\"_blank\">EGPS-2017<\/a> ELECTRON GUN POWER SUPPLY SPECIFICATIONS\uff1a<br \/>\n\t\tOUTPUT \uff1aAll necessary voltages to drive the High Energy EFG-7&nbsp;Electron Gun<br \/>\n\t\tENERGY STABILITY \uff1a&plusmn;0.01% per hour; &plusmn;0.02% per 8 hours at full output<br \/>\n\t\tBEAM STABILITY \uff1a&plusmn;0.1% per hour with Emission Current Control or&plusmn;10% per hour after warm up without ECC<br \/>\n\t\tCONTROLS FlexPanel controls: Energy, Source, Grid, Focus,&nbsp;Emission Current Control, optional X and Y Deflection<br \/>\n\t\tMETERING\uff1a FlexPanel digital meters: Energy, Source Voltage,Source Current, Emission Current, Grid, Focus,optional X and Y Deflection<br \/>\n\t\tCOMPUTER\/REMOTE&nbsp;CONTROL &amp; METER<br \/>\n\t\tPower supplies: 0 to +10 V (-10 V to +10 V, deflection)<br \/>\n\t\tMetering: 0 to +2 V ( -2 V to +2 V, deflection)<br \/>\n\t\tStandard 50-pin connector for analog input\/output and&nbsp;RS-232 serial port (RS-422 or RS-485 available, if&nbsp;specified at time of order)<br \/>\n\t\tOptional: SCSI metering and programming connectors<br \/>\n\t\tSOFTWARE \uff1aStandard configuration designed for RS-232&nbsp;connections.&nbsp;<br \/>\n\t\tOptional: National Instruments LabVIEWTM file, designed&nbsp;to run with computer DAQ boards NI PCI-6713 and&nbsp;PCIe-6341.SCSI connectors<br \/>\n\t\tINPUT 115 VAC or 230 VAC, 50 to 60 Hz single phase, 250 VA<br \/>\n\t\tENVIRONMENT \uff1aTemperature: 0 to 40&ordm;C, Relative humidity: 0 to 75% RH&nbsp;non condensing,&nbsp;<br \/>\n\t\tClassified as a pollution degree 2, installation category&nbsp;(overvoltage category) II environment unit<br \/>\n\t\tDIMENSIONS&nbsp;(width x height x depth)\uff1a<br \/>\n\t\t17 in. x 3.5 in. x 22 in. excluding handles&nbsp;<br \/>\n\t\t(425 mm x 90 mm x 560 mm); 19 in. rack mountable\n\t<\/p>\n<\/div>\n<br><div class=\"tagcloud\"><a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egg\/\" class=\"tag-cloud-link tag-link-0 tag-link-position-1\" style=\"font-size: 9.0769230769231pt;\" aria-label=\"EGG (93\u4e2a\u9879\u76ee)\">EGG<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egh\/\" class=\"tag-cloud-link tag-link-1 tag-link-position-2\" style=\"font-size: 9.2923076923077pt;\" aria-label=\"EGH (94\u4e2a\u9879\u76ee)\">EGH<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egl\/\" class=\"tag-cloud-link tag-link-2 tag-link-position-3\" style=\"font-size: 8.4307692307692pt;\" aria-label=\"EGL (86\u4e2a\u9879\u76ee)\">EGL<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egps\/\" class=\"tag-cloud-link tag-link-3 tag-link-position-4\" style=\"font-size: 8pt;\" aria-label=\"EGPS (83\u4e2a\u9879\u76ee)\">EGPS<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/emg\/\" class=\"tag-cloud-link tag-link-4 tag-link-position-5\" style=\"font-size: 8.6461538461538pt;\" aria-label=\"EMG (88\u4e2a\u9879\u76ee)\">EMG<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/kimball\/\" class=\"tag-cloud-link tag-link-5 tag-link-position-6\" style=\"font-size: 22pt;\" aria-label=\"kimball (367\u4e2a\u9879\u76ee)\">kimball<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/kimballphysics\/\" class=\"tag-cloud-link tag-link-6 tag-link-position-7\" style=\"font-size: 21.138461538462pt;\" aria-label=\"kimballphysics (339\u4e2a\u9879\u76ee)\">kimballphysics<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e5%a4%a7%e5%8a%9f%e7%8e%87%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-7 tag-link-position-8\" style=\"font-size: 16.615384615385pt;\" aria-label=\"\u5927\u529f\u7387\u7535\u5b50\u67aa (207\u4e2a\u9879\u76ee)\">\u5927\u529f\u7387\u7535\u5b50\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%89%ab%e6%8f%8f%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-8 tag-link-position-9\" style=\"font-size: 15.969230769231pt;\" aria-label=\"\u7535\u5b50\u626b\u63cf\u67aa (194\u4e2a\u9879\u76ee)\">\u7535\u5b50\u626b\u63cf\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9d%9f%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-9 tag-link-position-10\" style=\"font-size: 16.830769230769pt;\" aria-label=\"\u7535\u5b50\u675f\u7535\u5b50\u67aa (211\u4e2a\u9879\u76ee)\">\u7535\u5b50\u675f\u7535\u5b50\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-10 tag-link-position-11\" style=\"font-size: 17.476923076923pt;\" aria-label=\"\u7535\u5b50\u67aa (229\u4e2a\u9879\u76ee)\">\u7535\u5b50\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9e%aa%e6%9e%aa%e5%a4%b4\/\" class=\"tag-cloud-link tag-link-11 tag-link-position-12\" style=\"font-size: 12.738461538462pt;\" aria-label=\"\u7535\u5b50\u67aa\u67aa\u5934 (136\u4e2a\u9879\u76ee)\">\u7535\u5b50\u67aa\u67aa\u5934<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9e%aa%e7%94%b5%e6%ba%90\/\" class=\"tag-cloud-link tag-link-12 tag-link-position-13\" style=\"font-size: 16.615384615385pt;\" aria-label=\"\u7535\u5b50\u67aa\u7535\u6e90 (207\u4e2a\u9879\u76ee)\">\u7535\u5b50\u67aa\u7535\u6e90<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%9c%9f%e7%a9%ba%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-13 tag-link-position-14\" style=\"font-size: 16.4pt;\" aria-label=\"\u771f\u7a7a\u7535\u5b50\u67aa (205\u4e2a\u9879\u76ee)\">\u771f\u7a7a\u7535\u5b50\u67aa<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>Electron Gun System: 100 eV to 5000 eV Quick Overview Narrow-angle or uniform wide-angle b <\/p>\n","protected":false},"author":1,"featured_media":149,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[1],"tags":[22,24,23,20,21,12,11,26,18,25,17,16,15,19],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/posts\/148"}],"collection":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/comments?post=148"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/posts\/148\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/media\/149"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/media?parent=148"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/categories?post=148"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/tags?post=148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}