﻿{"id":146,"date":"2018-07-25T20:44:30","date_gmt":"2018-07-25T12:44:30","guid":{"rendered":"https:\/\/www.bihec.com\/kimballphysics\/?p=146"},"modified":"2019-06-17T23:05:29","modified_gmt":"2019-06-17T15:05:29","slug":"%e7%be%8e%e5%9b%bdkimball-physics%e5%85%ac%e5%8f%b8egl-2022-egps-2022%e7%94%b5%e5%ad%90%e6%9e%aa","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/kimballphysics\/%e7%be%8e%e5%9b%bdkimball-physics%e5%85%ac%e5%8f%b8egl-2022-egps-2022%e7%94%b5%e5%ad%90%e6%9e%aa\/","title":{"rendered":"EGL-2022 \/ EGPS-2022\u7535\u5b50\u67aa"},"content":{"rendered":"<div class=\"product-name\" style=\"font-size: 14px; font-weight: bold; line-height: 14px; color: rgb(68, 68, 68); margin: 0px 0px 10px; font-family: Arial, Helvetica, sans-serif;\">\n<h5 style=\"float: none; font-size: 12px; margin: 0px; color: rgb(120, 122, 129) !important;\">\n\t\tElectron Gun System: 50 eV to 5000 eV<br \/>\n\t<\/h5>\n<\/div>\n<div class=\"short-description std\" style=\"line-height: 17px; color: rgb(85, 85, 85); font-family: Arial, Helvetica, sans-serif; padding: 10px 0px 0px;\">\n<h3 style=\"float: none; color: rgb(120, 122, 129); font-size: 12px; font-weight: bold; line-height: normal; margin: 0px 0px 5px;\">\n\t\tQuick Overview<br \/>\n\t<\/h3>\n<p>\n\t\tConstant beam current and spot size over broad energy range<\/p>\n<p>\t\t<strong>Energy Range:<\/strong>&nbsp;50 eV to 5000 eV<br \/>\n\t\t<strong>Beam Current:<\/strong>&nbsp;1 nA to 100 &micro;A<br \/>\n\t\t<strong>Spot Sizes:<\/strong>&nbsp;1 mm to 10 mm<br \/>\n\t\t<strong>Mounting:<\/strong>&nbsp;2&frac34;CF<br \/>\n\t\t<strong>Features\/Options:<\/strong>&nbsp;Zoom Lens Focusing for Energy Sweeping, Deflection, Rastering, High Speed Pulsing\n\t<\/p>\n<p>\n\t\t&nbsp;\n\t<\/p>\n<p>\n\t\tFOR USE IN:<br \/>\n\t\t\uf034Surface Physics Studies<br \/>\n\t\t\uf034Ionization Experiments<br \/>\n\t\t\uf034Charge neutralization\n\t<\/p>\n<p>\n\t\tFEATURES \/ OPTIONS:<br \/>\n\t\t\uf034Wide Energy range<br \/>\n\t\t\uf034Constant Beam Current<br \/>\n\t\t\uf034Constant Spot Size<br \/>\n\t\t\uf034Zoom Lens Focusing<br \/>\n\t\t\uf034High Speed Pulsing<br \/>\n\t\t\uf034Deflection, Rastering<br \/>\n\t\t\uf034Computer \/ Remote Control\n\t<\/p>\n<p>\n\t\t<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egl-2022\/\" title=\"View all posts in EGL-2022\" target=\"_blank\">EGL-2022<\/a> ELECTRON GUN SPECIFICATIONS\uff1a<br \/>\n\t\tBEAM ENERGY \uff1a50 eV to 5 keV (Independently adjustable)<br \/>\n\t\tBEAM CURRENT \uff1aStandard: 1 nA to 100 &mu;A (Independently adjustable)<br \/>\n\t\tENERGY SPREAD\uff1a<br \/>\n\t\tApprox. cathode thermal spread, calculated&nbsp;<br \/>\n\t\tTa &#8211; 0.5eV <a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/y2o3\/\" title=\"View all posts in Y2O3\" target=\"_blank\">Y2O3<\/a> &#8211; 0.4eV&nbsp;<br \/>\n\t\tBaO &#8211; 0.3eV LaB6 &#8211; 0.4eV<br \/>\n\t\tSPOT SIZE \uff1a1 mm to 10 mm (Independently adjustable)<br \/>\n\t\tWORKING DISTANCE \uff1aVariable: 20 mm to 100 mm<br \/>\n\t\tBEAM DEFLECTION \uff1a4 pole electrostatic: &plusmn; 3.5&deg; at 5 keV; scales larger at&nbsp;lower energies<br \/>\n\t\tPULSE CAPABILITY(using appropriate&nbsp;pulse generator,&nbsp;not included)\uff1a<br \/>\n\t\tOptional capacitive Pulse Junction Box: pulse width&nbsp;20 ns to 100 &mu;s , rise\/ fall 10 ns, 50 &Omega; impedance, 1 W&nbsp;standard (higher power available)<br \/>\n\t\tOptional Dual Grid Power Supply: pulse width 2 &mu;s to&nbsp;DC, rise\/ fall 500 ns, rep rates to 5kHz (TTL required)<br \/>\n\t\tBEAM UNIFORMITY \uff1aGaussian<br \/>\n\t\tFIRING UNIT\uff1a<br \/>\n\t\tCustomer-replaceable Firing Unit includes&nbsp;precision-aligned cathode and Wehnelt (G-1) assembly,with insulators and connectors<br \/>\n\t\tCATHODE TYPES\uff1a<br \/>\n\t\tStandard: <a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/tantalum\/\" title=\"View all posts in Tantalum\" target=\"_blank\">Tantalum<\/a> disc<br \/>\n\t\tOptional: Lanthanum hexaboride (LaB6),&nbsp;Barium oxide (BaO), or Yttrium oxide (Y2O3) With the&nbsp;exception of Barium oxide, cathodes not harmed by&nbsp;repeated exposure to atmospheric gases while cold<br \/>\n\t\tMOUNTING\uff1a<br \/>\n\t\tFlange Multiplexer with a 2&frac34; inch rotatable CF,including both tapped and clear mounting holes.<br \/>\n\t\tOptional unmounted model with 9 in-vacuum leads.<br \/>\n\t\tBEAM ALIGNMENT Optional: Mechanical alignment with &plusmn; 2&deg; Port Aligner<br \/>\n\t\tINSERTION LENGTH<br \/>\n\t\tStandard: 200 mm, Range: 200 mm to 300 mm.&nbsp;Custom lengths available. Gun manufactured at&nbsp;standard length unless otherwise specified at time of&nbsp;order.&nbsp;<br \/>\n\t\tGUN DIAMETER \uff1a34 mm, gun tube in vacuum<br \/>\n\t\tFEEDTHROUGHS\uff1a Multi-pin brazed ceramic, threaded stainless steel shell<br \/>\n\t\tCABLES \/CONNECTORS<br \/>\n\t\tMulti-conductor high voltage fully ground-shielded cable,coaxial grid cable, low voltage deflection cable, with&nbsp;mating aluminum shell connectors, to connect gun and&nbsp;power supply.\n\t<\/p>\n<p>\n\t\tStandard lengths: 3 m Optional: 5 m&nbsp;<br \/>\n\t\tMAXIMUM BAKEOUT \uff1a350&deg;C with cables removed\n\t<\/p>\n<p>\n\t\t&nbsp;\n\t<\/p>\n<p>\n\t\t<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egps-2022\/\" title=\"View all posts in EGPS-2022\" target=\"_blank\">EGPS-2022<\/a> ELECTRON GUN POWER SUPPLY SPECIFICATIONS\uff1a<br \/>\n\t\tOUTPUT All necessary voltages to drive the <a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egl\/\" title=\"View all posts in EGL\" target=\"_blank\">EGL<\/a>-2022 Electron&nbsp;Gun<br \/>\n\t\tENERGY STABILITY\uff1a &plusmn;0.01% per hour; &plusmn;0.02% per 8 hours at full output<br \/>\n\t\tBEAM STABILITY\uff1a &plusmn;0.1% per hour with Emission Current Control or&nbsp;&plusmn;10% per hour after warm up without ECC<br \/>\n\t\tCONTROLS \uff1aFlexPanel controls: Energy, Source, Grid, First Anode,Focus, X and Y Deflection, Emission Current Control<br \/>\n\t\tMETERING\uff1a<br \/>\n\t\tFlexPanel digital meters: Energy, Source Voltage,Source Current, Emission Current, Grid,&nbsp;First Anode Voltage, Focus, X and Y Deflection<br \/>\n\t\tCOMPUTER\/REMOTE&nbsp;CONTROL &amp; METER<br \/>\n\t\tPower supplies: 0 to +10 V (-10 V to +10 V, deflection)<br \/>\n\t\tMetering: 0 to +2 V ( -2 V to +2 V, deflection)<br \/>\n\t\tStandard 50-pin connector for analog input\/output and&nbsp;RS-232 serial port (RS-422 or RS-485 available, if&nbsp;specified at time of order)<br \/>\n\t\tOptional: SCSI metering and programming connectors<br \/>\n\t\tSOFTWARE\uff1a Standard configuration designed for RS-232&nbsp;connections.&nbsp;<br \/>\n\t\tOptional: National Instruments LabVIEWTM file, designed&nbsp;to run with computer DAQ boards NI PCI-6713 and &nbsp;PCIe-6341. SCSI connections.<br \/>\n\t\tINPUT 115 VAC or 230 VAC, 50 to 60 Hz single phase, 250 VA<br \/>\n\t\tENVIRONMENT \uff1aTemperature: 0 to 40&ordm;C, Relative humidity: 0 to 75% RH&nbsp;non condensing,&nbsp;<br \/>\n\t\tClassified as a pollution degree 2, installation category&nbsp;(overvoltage category) II environment unit<br \/>\n\t\tDIMENSIONS(width x height x depth);<br \/>\n\t\t17 in. x 3.5 in. x 22 in. excluding handles&nbsp;<br \/>\n\t\t(425 mm x 90 mm x 560 mm); 19 in. rack mountable\n\t<\/p>\n<\/div>\n<br><div class=\"tagcloud\"><a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egg\/\" class=\"tag-cloud-link tag-link-0 tag-link-position-1\" style=\"font-size: 9.0769230769231pt;\" aria-label=\"EGG (93\u4e2a\u9879\u76ee)\">EGG<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egh\/\" class=\"tag-cloud-link tag-link-1 tag-link-position-2\" style=\"font-size: 9.2923076923077pt;\" aria-label=\"EGH (94\u4e2a\u9879\u76ee)\">EGH<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egl\/\" class=\"tag-cloud-link tag-link-2 tag-link-position-3\" style=\"font-size: 8.4307692307692pt;\" aria-label=\"EGL (86\u4e2a\u9879\u76ee)\">EGL<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/egps\/\" class=\"tag-cloud-link tag-link-3 tag-link-position-4\" style=\"font-size: 8pt;\" aria-label=\"EGPS (83\u4e2a\u9879\u76ee)\">EGPS<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/emg\/\" class=\"tag-cloud-link tag-link-4 tag-link-position-5\" style=\"font-size: 8.6461538461538pt;\" aria-label=\"EMG (88\u4e2a\u9879\u76ee)\">EMG<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/kimball\/\" class=\"tag-cloud-link tag-link-5 tag-link-position-6\" style=\"font-size: 22pt;\" aria-label=\"kimball (367\u4e2a\u9879\u76ee)\">kimball<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/kimballphysics\/\" class=\"tag-cloud-link tag-link-6 tag-link-position-7\" style=\"font-size: 21.138461538462pt;\" aria-label=\"kimballphysics (339\u4e2a\u9879\u76ee)\">kimballphysics<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e5%a4%a7%e5%8a%9f%e7%8e%87%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-7 tag-link-position-8\" style=\"font-size: 16.615384615385pt;\" aria-label=\"\u5927\u529f\u7387\u7535\u5b50\u67aa (207\u4e2a\u9879\u76ee)\">\u5927\u529f\u7387\u7535\u5b50\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%89%ab%e6%8f%8f%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-8 tag-link-position-9\" style=\"font-size: 15.969230769231pt;\" aria-label=\"\u7535\u5b50\u626b\u63cf\u67aa (194\u4e2a\u9879\u76ee)\">\u7535\u5b50\u626b\u63cf\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9d%9f%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-9 tag-link-position-10\" style=\"font-size: 16.830769230769pt;\" aria-label=\"\u7535\u5b50\u675f\u7535\u5b50\u67aa (211\u4e2a\u9879\u76ee)\">\u7535\u5b50\u675f\u7535\u5b50\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-10 tag-link-position-11\" style=\"font-size: 17.476923076923pt;\" aria-label=\"\u7535\u5b50\u67aa (229\u4e2a\u9879\u76ee)\">\u7535\u5b50\u67aa<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9e%aa%e6%9e%aa%e5%a4%b4\/\" class=\"tag-cloud-link tag-link-11 tag-link-position-12\" style=\"font-size: 12.738461538462pt;\" aria-label=\"\u7535\u5b50\u67aa\u67aa\u5934 (136\u4e2a\u9879\u76ee)\">\u7535\u5b50\u67aa\u67aa\u5934<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%94%b5%e5%ad%90%e6%9e%aa%e7%94%b5%e6%ba%90\/\" class=\"tag-cloud-link tag-link-12 tag-link-position-13\" style=\"font-size: 16.615384615385pt;\" aria-label=\"\u7535\u5b50\u67aa\u7535\u6e90 (207\u4e2a\u9879\u76ee)\">\u7535\u5b50\u67aa\u7535\u6e90<\/a>\n<a href=\"https:\/\/www.bihec.com\/kimballphysics\/tag\/%e7%9c%9f%e7%a9%ba%e7%94%b5%e5%ad%90%e6%9e%aa\/\" class=\"tag-cloud-link tag-link-13 tag-link-position-14\" style=\"font-size: 16.4pt;\" aria-label=\"\u771f\u7a7a\u7535\u5b50\u67aa (205\u4e2a\u9879\u76ee)\">\u771f\u7a7a\u7535\u5b50\u67aa<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>Electron Gun System: 50 eV to 5000 eV Quick Overview Constant beam current and spot size o <\/p>\n","protected":false},"author":1,"featured_media":147,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[1],"tags":[22,24,23,20,21,12,11,26,18,25,17,16,15,19],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/posts\/146"}],"collection":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/comments?post=146"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/posts\/146\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/media\/147"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/media?parent=146"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/categories?post=146"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/kimballphysics\/wp-json\/wp\/v2\/tags?post=146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}