Horst Temperature Regulators 温度调节器 温度控制器 适用于固定用途的温度调节器 HT MC11 – Microprocessor Temperature Regulator

Horst Temperature Regulators 温度调节器 温度控制器 适用于固定用途的温度调节器

HT MC11 – Microprocessor Temperature Regulator

咨询热线 15821107090

HT MC11 是一款温度调节器,可投入运行,其温度监控独立于调节功能,采用独立的温度传感器输入和加热电流监测功能(可选)。
紧凑的铝制外壳防护等级达 IP 65,高度可配置,以及多种连接选项和功能,使其广泛应用于电加热元件的温度控制与监测。
为实现快速便捷的启动,HT MC11 出厂时已预先配置好并适配其预期用途。

 

Functions and features

HousingPowder coated aluminum, protection category IP 65
Control electronicsTwo-position-regulator, PID control characteristics
Self-optimizationAutomatic determination of control parameters (Autotune)
OperationUsing keypad
Temperature supervisionTemperature supervision with second sensor input, adjustable limit value, two-pole disconnection of heating voltage
ConnectionsHeating and temperature sensor connection via multipole sockets or cable glands, connection board with spring terminals inside the housing
Switching powerUp to 3450 Watt (at 230 VAC), electronically switched
Temperature sensorIndependently selectable for regulation and supervision, Resistance sensor Pt100, NI120, Pt1000 (only for regulation), Thermocouple Fe-CuNi (L), Fe-CuNi (J), NiCr-Ni (K), PtRh-Pt (S), NiCr-NiSi (N)
Potential-free switchingHeating voltages 24-250 VAC (10 A or 15 A depending on model) can be switched independently from the auxiliary voltage of the control electronics.
Program function6 * ramp time + hold time
Softstart functionFor smooth heating-up
Alarm relayPotential-free normally open contact, 250 V, max. 2 A
Output ratio displayShows the present calculated output ratio in 0…100 %
Max. output ratio limitationReduces the connected heating output
Manual output ratio modeIn case of sensor break, operation continues with last calculated output ratio
Manual modeDevice operates as a power controller
Operation lockAvailable on three levels
SetpointsSetpoint 1, setpoint 2 (can be activated by external contact), external setpoint (only for option „analog input/output“)
Second parameter setPossible (can be activated by external contact)
CE markingEMV according to 2004/108/EG; EN 61326-1, Electrical safety EN 61010-1

 