Horst Temperature Regulators 温度调节器 温度控制器 前面板集成温度调节器
HT MC11 S19
咨询热线 15821107090
系统机箱用微处理器温度调节器
HT MC11 S19 是一款预接线组件,其调节特性与 HT MC11 相同。在启动前,必须将其安装并连接到合适的系统机箱中。除调节电子元件外,它还配备一个用于切换负载的固态继电器、一个在出现故障时切断主电源加热的两极机械继电器,以及正面的一个可更换保险丝。背面的连接板通过弹簧端子实现轻松连接。也适用于多个控制电路,或在桌面或壁挂式机箱中预接线,可直接投入使用。
Functions and features
Housing: | Powder coated aluminum, protection category IP 00 |
Control electronics: | Two-position-regulator, PID control characteristics |
Self-optimization: | Automatic determination of control parameters (Autotune) |
Operation: | Using keypad |
Temperature supervision: | Temperature supervision with second sensor input, adjustable limit value, two-pole disconnection of heating voltage |
Connections: | Heating and temperature sensor connection via multipole sockets or cable glands, connection board with spring terminals inside the housing |
Switching power: | Up to 3450 Watt (at 230 VAC), electronically switched |
Temperature sensor: | Independently selectable for regulation and supervision, Resistance sensor Pt100, NI120, Pt1000, Thermocouple Fe-CuNi (L), Fe-CuNi (J), NiCr-Ni (K), PtRh-Pt (S), NiCr-NiSi (N) |
Potential-free switching: | Heating voltages 24-250 VAC (10 A or 15 A depending on model) can be switched independently from the auxiliary voltage of the control electronics. |
Program function: | 6 * ramp time + hold time |
Softstart function: | For smooth heating-up |
Alarm relay: | Potential-free normally open contact, 250 V, max. 2 A |
Output ratio display: | Shows the present calculated output ratio in 0…100 % |
Max. output ratio limitation: | Reduces the connected heating output |
Manual output ratio mode: | In case of sensor break, operation continues with last calculated output ratio |
Manual mode: | Device operates as a power controller |
Operation lock: | Available on three levels |
Setpoints: | Setpoint 1, setpoint 2 (can be activated by external contact), external setpoint (only for option „analog input/output“) |
Second parameter set: | Possible (can be activated by external contact) |
CE marking: | EMV according to 2004/108/EG; EN 61326-1, Electrical safety EN 61010-1 |