Olis, Inc OLIS DSM 172 UV/VIS/NIR CD & CPL SPECTROPHOTOMETER 紫外/可见光/红外 圆二色/CPL光谱仪

The OLIS DSM acquisition achieves zero drift, near-perfect baseline flatness, and outstanding S/N quickly. Spectral data collection rates start at 0.1 second per datum during scanning and kinetic data collection rates are up to 1,000 points per second. All electronics and software are optimized for sensitivity and speed, including a 16 bit, 500 kHz analog-to-digital card. Fully digital design means that all sorting, summing, ratioing, logarithms, noise filtering, et cetera, of raw digital data are done by the OLIS CD SpectralWorks program, our fully Windows 7 Pro compatible software for providing maximum precision in operation and data handling. The sample compartment is the "Polarization Toolbox," which uniquely offers the freedom to position the polarizers and photoelastic modular not only for CD but in those positions supporting Circularly Polarized Luminescence and Polarization of Fluorescence. These secondary measurements support study of the molecules in their excited state using an electro-optical method which acquires L-format polarization of fluorescence and anisotropy directly without G-factor corrections, as well as fluorescence detected circular dichroism (FDCD) and CPL. The optical bench is the premium prism-grating double monochromator by CARY with an available spectral range of 185-2600 nm fitted with a 150 watt xenon arc lamp, regulated power supply and ignitor. For UV CD of protein, peptide, nucleic acid studies, the spectral data are acquired with the best detector extent: a UV optimized photomultiplier tube. For NIR scanning (800-1700), the fast response, low noise InGaAs detector can be purchased and added. The emission wavelength selector is a compact single grating monochromator to support scanning emission work and for ease of selection of any appropriate emission wavelength. This monochromator can be set to zero, and thereby act as a mirror. It can be for any emission from approximately 300-800 nm with or without associated scanning. Should higher stray light rejection ever be required, a filter can be inserted in the filter holder, producing a double monochromator. The detector for emission (e.g., FDCD and CPL) is a high sensitivity gated photon counting detector with spectral range of 230-850 nm. The counts streaming from the photon counting photomultiplier are alternately routed to a 'left' counter and a 'right' counter in synchrony and in appropriate phase relationship to the operation of the PEM in the analyzer's optical train. Left and right counts are accumulated until a useful signal-to-noise ratio has been achieved. CPL data acquisition can last hours and longer, so the absolute stability of the Olis method greatly enhances the likelihood of successful results. The software is a comprehensive data acquisition/analysis/instrument control program which is easy to use and dense with useful functions. Everything for 2D and 3D data acquisition and analysis is included. After spectra are acquired, they can be saved as binary, ASCII, Excel, or JPG. Analysis options include three popular algorithms for secondary structure determination (SELCON3, CONTINLL, and VARSLC) and an exhaustive selection of 2D data manipulation choices (smoothing, derivatives, exponentials, subtraction, etc.) as well as kinetic fits. Three dimensional data acquired during thermal melts, chemical denaturation, and kinetic studies are analyzed with Singular Value Decomposition (SVD) to determine the number of species in the reaction, followed by Downhill Simplex and Matrix Exponentiation for spectral reconstruction of the starting, final, and any spectral intermediate forms. The Olis Supplied Computer System: OLIS verified and supported desktop PC with 3rd Gen. Intel Core i3-3240 3.4GHz, 4GB DDR3, 1TB HDD 7,200RPM, DVD-RW drive, 6 Total USB 2.0 Ports. Windows 7 Pro 64-bit (English version required) Base of the instrument dimensions are approximately 51 x 22". First year warranty covers all issues; a modestly priced Warranty Renewable Package is available on an annual basis. Made in the USA
Olis, Inc OLIS DSM 172 UV/VIS/NIR CD & CPL SPECTROPHOTOMETER 紫外/可见光/红外 圆二色/CPL光谱仪

询价采购Olis, Inc OLIS DSM 172 UV/VIS/NIR CD & CPL SPECTRO

请微信扫描下方二维码或手动添加微信号2351992198

关于我们

每天我们都在世界各地采购重要的货品,通过设于欧洲、美国、香港、上海的办公室,将全球工业产品带到中国。原厂直接采购,一手货源,最低出厂价、最快交期,让客户进口采购变得省钱、省时、省心。

Next

业务范围

我们为各行业客户提供专业的进口采购、付汇结算、报关报检、仓储物流的数字化采购解决方案。

Next

服务优势

行业领先的公司采用我们的平台和服务,通过我们全球多个办事处采购企业发展所需的物资,缩短供应链货期,以提高效率和控制成本。

Next

联系Olis, Inc OLIS DSM 172 UV/VIS/NIR CD & CPL SPECTRO

微信扫描下方二维码或手动添加微信号2351992198