The Bionetics Corporation, formerly Intek, Inc. 210R-XDT-BF/2I(400F)(1"#150-RF)-JB(SS)-HART-24V-ISB-5M 210R-XDT-BF/2I(400F)(1-150RF)
Consisting of flow sensing transducer, separate electronics package, and interconnect cable
Flow Data
Fluid: Nitrogen
Customer Line Size: 24inch
Customer Flow Range: 0 - 600 Nm3/hr
Calibrated Flow Range: 30 - 600 Nm3/hr
Temperature - Max Requirement: 204℃
Temperature - Operating Range: 15.5℃
Pressure - Max Requirement: 55 PSIG
Pressure - Operating Range: 5 PSIG
Fluid Viscosity: 0.017338 cp
Fluid Density: 1.5852 kg/m^3
Instrument Data
Transducer Type: Insertion Probe
Wetted Material: SS 316
Process Connection: ASME B16.5 Raised Face Flange #150: 1"
Local Display: selectable Flow Rate, Totalizer and Fluid Temperature
Calibration Units: Nm3/hr.
Outputs: HART
Input Power: 24VDC
Electronics Enclosure: NEMA 7X
Cable Length: 5m; (付费可升级至200 ft)
Calculated for 12-inch Sch 40 pipe | Min. | Nom. | Max. |
Measuring Range: | 30 Nm3/hr | 68 Nm3/hr | 600 Nm3/hr |
Velocity: | 0.12 m/s | 0.27 m/s | 2.36 m/s |
Measurement Uncertainty*: | ±3.8% | ±2.0% | ±3.9% |
Pressure Drop caused by probe tip*: | Negligible | Negligible | Negligible |
*Based on Nitrogen and nominal temperature of 15.5℃±10℃.