The Bionetics Corporation, formerly Intek, Inc. 210R-IDT-BF/2I(MO)-4/20-220V 插入式热式流量计
Flow Data:
Fluid: Freon R-350 (See Note 1)
Customer Line Size: 150 mm I.D. (See Note 2)
Customer Flow Range: 40 kg/h
Calibrated Flow Range: 8-120 kg/hr
Temperature-Max: 20 C
Temperature-Operating Range: 16-20 C
Pressure-Max: 1000 Pa
Pressure-Operating range: 700-1000 Pa
Viscosity: TBD
Specific Gravity: TBD
Instrument Data:
Transducer Type: Insertion Probe
Wetted Material: Monel (See Note 3)
Fittings: 1-inch 150 pound raised face flange
Local Display: 2x16 character LCD with Flow Rate, Totalizer and Flow Rate
Calibration Units: kg/hr
Output(s): 4 to 20 milliamp
Input Power: 220 VAC 50 Hz
Electronics Enclosure: NEMA 4
Cable Length: 10 ft;
Special Features:
Insertion Length: Dimension X is 115mm on DWG 93091 (See Note 4)