﻿{"id":220,"date":"2025-04-08T18:08:34","date_gmt":"2025-04-08T10:08:34","guid":{"rendered":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/?p=220"},"modified":"2025-04-08T18:08:34","modified_gmt":"2025-04-08T10:08:34","slug":"%e4%bb%a3%e7%90%86applied-scientific-instrumentation-asi-ls-400%e7%94%b5%e6%8e%a7%e7%ba%bf%e6%80%a7%e4%bd%8d%e7%a7%bb%e5%b9%b3%e5%8f%b0","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/%e4%bb%a3%e7%90%86applied-scientific-instrumentation-asi-ls-400%e7%94%b5%e6%8e%a7%e7%ba%bf%e6%80%a7%e4%bd%8d%e7%a7%bb%e5%b9%b3%e5%8f%b0\/","title":{"rendered":"\u4ee3\u7406Applied Scientific Instrumentation ASI LS-400\u7535\u63a7\u7ebf\u6027\u4f4d\u79fb\u5e73\u53f0"},"content":{"rendered":"<h2>\u4ee3\u7406<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/applied-scientific-instrumentation\/\" title=\"View all posts in Applied Scientific Instrumentation\" target=\"_blank\">Applied Scientific Instrumentation<\/a> <a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-ls-400\/\" title=\"View all posts in ASI LS-400\" target=\"_blank\">ASI LS-400<\/a>\u7535\u63a7\u7ebf\u6027\u4f4d\u79fb\u5e73\u53f0<\/h2>\n<div class=\"special-heading-border\">\n<div class=\"special-heading-border\">\n<p><span id=\"dtlview_\u4f9b\u5e94\u5546\u540d\u79f0\"><a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/applied-scientific-instrumentation%e6%98%be%e5%be%ae%e9%95%9c\/\" title=\"View all posts in Applied Scientific Instrumentation\u663e\u5fae\u955c\" target=\"_blank\">Applied Scientific Instrumentation\u663e\u5fae\u955c<\/a>\u7ebf\u6027\u4f4d\u79fb<\/span>\u5e73\u53f0\u5229\u7528\u4ea4\u53c9\u6eda\u67f1\u6ed1\u52a8\uff0c\u7cbe\u5bc6\u5bfc\u87ba\u6746\uff0c\u548c\u96f6\u9f7f\u9699\u5fae\u578b\u9f7f\u8f6e\u76f4\u6d41\u4f3a\u670d\u7535\u673a\uff0c\u5b9e\u73b0\u5e73\u7a33\u51c6\u786e\u7684\u8fd0\u52a8\u3002\u8fd9\u4e9b\u88c5\u7f6e\u63d0\u4f9b\u4ece50\u6beb\u7c73\u5230300\u6beb\u7c73\uff082\u82f1\u5bf8\u523012\u82f1\u5bf8\uff09\u7684\u7cbe\u786e\u884c\u7a0b\u3002\u5b83\u4eec\u53ef\u4ee5\u5355\u72ec\u4f7f\u7528\uff0c\u4e5f\u53ef\u4ee5\u5806\u53e0\u4f7f\u7528\uff0c\u5782\u76f4\u6216\u6c34\u5e73\u4f7f\u7528\uff0c\u6700\u591a\u53ef\u627f\u8f7d4.5\u516c\u65a4\uff0810\u78c5\uff09\u7684\u8d1f\u8f7d\u3002<\/p>\n<p>ASI LS\u7cfb\u5217\u7535\u63a7\u7ebf\u6027\u4f4d\u79fb\u5e73\u53f0\u5177\u6709\u5185\u7f6e\u9650\u4f4d\u5f00\u5173\uff0c\u53ef\u4ee5\u914d\u7f6e\u4e0b\u8868\u4e2d\u5217\u51fa\u7684\u8bb8\u591a\u5bfc\u87ba\u6746\u9009\u9879\u3002\u5728\u6807\u51c6\u65cb\u8f6c\u7f16\u7801\u5668\u914d\u7f6e\u4e2d\uff0c\u4f7f\u7528ASI\u7684MS-2000\u63a7\u5236\u7535\u5b50\u8bbe\u5907\uff0c\u53ef\u4ee5\u8f7b\u677e\u83b7\u5f9750-100nm\u8303\u56f4\u5185\u7684\u5206\u8fa8\u7387\u3002\u8fd8\u53ef\u83b7\u5f97\u5c0f\u4e8e300nm RMS\u7684\u91cd\u590d\u6027\u56e0\u7d20\u3002<\/p>\n<p>\u53ef\u9009\u7684\u7ebf\u6027\u7f16\u7801\u5668\u63d0\u4f9b10 nm\u7684\u6807\u5c3a\u5206\u8fa8\u7387\uff0c\u6bcf\u4e2a\u6807\u5c3a\u957f\u5ea6\u7684\u6807\u5c3a\u7cbe\u5ea6\u4e3a\u00b13\u03bcm\u3002<\/p>\n<\/div>\n<\/div>\n<div>\n<p><strong>\u7f8e\u56fdASI LS-Series \u7535\u63a7\u7ebf\u6027\u4f4d\u79fb\u5e73\u53f0\u89c4\u683c\uff1a<\/strong><\/p>\n<table border=\"1\" width=\"900\">\n<tbody>\n<tr>\n<td>Specifications<\/td>\n<td>LS-25<\/td>\n<td>LS-50<\/td>\n<td>LS-100<\/td>\n<td>LS-200<\/td>\n<td>LS-400<\/td>\n<\/tr>\n<tr>\n<td>Encoder resolution*<\/td>\n<td>5.0 nm<\/td>\n<td>5.5 nm<\/td>\n<td>5.5 nm<\/td>\n<td>5.5 nm<\/td>\n<td>5.5 nm (.0055 \u00b5m<sup>\u2020<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td>With linear encoder<\/td>\n<td>10 nm<\/td>\n<td>10 nm<\/td>\n<td>10 nm<\/td>\n<td>10 nm<\/td>\n<td>10 nm<\/td>\n<\/tr>\n<tr>\n<td>RMS repeatability (typical)*<\/td>\n<td>&lt; 0.7 \u03bcm<\/td>\n<td>&lt; 0.7 \u03bcm<\/td>\n<td>&lt; 0.7 \u03bcm<\/td>\n<td>&lt; 0.7 \u03bcm<\/td>\n<td>&lt; 0.7 \u03bcm (&lt; 8.0 \u03bcm<sup>\u2020<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td>With linear encoder (typical)<\/td>\n<td>200 nm<\/td>\n<td>200 nm<\/td>\n<td>200 nm<\/td>\n<td>200 nm<\/td>\n<td>200 nm<\/td>\n<\/tr>\n<tr>\n<td>Lead screw accuracy<\/td>\n<td>0.25 \u03bcm\/mm<\/td>\n<td>0.25 \u03bcm\/mm<\/td>\n<td>0.25 \u03bcm\/mm<\/td>\n<td>0.25 \u03bcm\/mm<\/td>\n<td>0.25 \u03bcm\/mm<\/td>\n<\/tr>\n<tr>\n<td>With linear encoder<\/td>\n<td>\u00b1 3 \u03bcm\/length scale<\/td>\n<td>\u00b1 3 \u03bcm\/length scale<\/td>\n<td>\u00b1 3 \u03bcm\/length scale<\/td>\n<td>\u00b1 3 \u03bcm\/length scale<\/td>\n<td>\u00b1 3 \u03bcm\/length scale<\/td>\n<\/tr>\n<tr>\n<td>Maximum velocity*<\/td>\n<td>1.60 mm\/s<\/td>\n<td>1.75 mm\/s<\/td>\n<td>1.75 mm\/s<\/td>\n<td>1.75 mm\/s<\/td>\n<td>1.75 mm\/s<\/td>\n<\/tr>\n<tr>\n<td>Range of travel<\/td>\n<td>25 mm (1\u201d)<\/td>\n<td>50 mm (2\u201d)<\/td>\n<td>100 mm (4\u201d)<\/td>\n<td>200 mm (8\u201d)<\/td>\n<td>400 mm (16\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Length<\/td>\n<td>86 mm (3.4\u201d)<\/td>\n<td>152.5 mm (6\u201d)<\/td>\n<td>203.5 mm (8\u201d)<\/td>\n<td>305 mm (12\u201d)<\/td>\n<td>594.5 mm (23.4\u201d)<\/td>\n<\/tr>\n<tr>\n<td>With connector**<\/td>\n<td>137 mm (5.4\u201d)<\/td>\n<td>233 mm (9.2\u201d)<\/td>\n<td>286 mm (11.3\u201d)<\/td>\n<td>369 mm (14.5\u201d)<\/td>\n<td>675 mm (26.6\u201d)<\/td>\n<\/tr>\n<tr>\n<td>With RA connector**<\/td>\n<td>\u2014\u2013<\/td>\n<td>195 mm (7.6\u201d)<\/td>\n<td>247 mm (9.7\u201d)<\/td>\n<td>380 mm (15\u201d)<\/td>\n<td>363 mm (25\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Width<\/td>\n<td>68.5 mm (2.7\u201d)<\/td>\n<td>68.5 mm (2.7\u201d)<\/td>\n<td>68.5 mm (2.7\u201d)<\/td>\n<td>68.5 mm (2.7\u201d)<\/td>\n<td>150 mm (5.9\u201d)<\/td>\n<\/tr>\n<tr>\n<td>With connector**<\/td>\n<td>120 mm (4.7\u201d)<\/td>\n<td>132.5 mm (5.2\u201d)<\/td>\n<td>132.5 mm (5.2\u201d)<\/td>\n<td>132.5 mm (5.2\u201d)<\/td>\n<td>215 mm (8.5\u201d)<\/td>\n<\/tr>\n<tr>\n<td>With RA connector**<\/td>\n<td>\u2014\u2013<\/td>\n<td>93.5 mm (3.7\u201d)<\/td>\n<td>93.5 mm (3.7\u201d)<\/td>\n<td>93.5 mm (3.7\u201d)<\/td>\n<td>175 mm (6.9\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Height<\/td>\n<td>35.5 mm (1.4\u201d)<\/td>\n<td>30 mm (1.2\u201d)<\/td>\n<td>30 mm (1.2\u201d)<\/td>\n<td>30 mm (1.2\u201d)<\/td>\n<td>50 mm (2\u201d)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>0.5 kg (1 lb)<\/td>\n<td>1.4 kg (3 lb)<\/td>\n<td>1.9 kg (4 lb)<\/td>\n<td>2.4 kg (6 lb)<\/td>\n<td>9 kg (20 lb)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-185\" src=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-300x225.jpg 300w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-1024x768.jpg 1024w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-768x576.jpg 768w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-1536x1152.jpg 1536w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-2048x1536.jpg 2048w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-500x375.jpg 500w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-800x600.jpg 800w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-1280x960.jpg 1280w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1528171-1920x1440.jpg 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-184\" src=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-300x225.jpg 300w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-1024x768.jpg 1024w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-768x576.jpg 768w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-1536x1152.jpg 1536w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-2048x1536.jpg 2048w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-500x375.jpg 500w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-800x600.jpg 800w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-1280x960.jpg 1280w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1527331-1920x1440.jpg 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-197\" src=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-300x225.jpg\" alt=\"ASI\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-300x225.jpg 300w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-1024x768.jpg 1024w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-768x576.jpg 768w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-1536x1152.jpg 1536w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-2048x1536.jpg 2048w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-500x375.jpg 500w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-800x600.jpg 800w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-1280x960.jpg 1280w, https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-content\/uploads\/sites\/755\/2024\/07\/IMG_20240701_1532141-1-1920x1440.jpg 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<\/div>\n<br><div class=\"tagcloud\"><a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-ls-200\/\" class=\"tag-cloud-link tag-link-0 tag-link-position-1\" style=\"font-size: 13.6pt;\" aria-label=\"ASI LS-200 (9\u4e2a\u9879\u76ee)\">ASI LS-200<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-ls-400\/\" class=\"tag-cloud-link tag-link-1 tag-link-position-2\" style=\"font-size: 8pt;\" aria-label=\"ASI LS-400 (4\u4e2a\u9879\u76ee)\">ASI LS-400<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e5%85%89%e7%89%87%e7%85%a7%e6%98%8e%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-2 tag-link-position-3\" style=\"font-size: 20.693333333333pt;\" aria-label=\"ASI\u5149\u7247\u7167\u660e\u663e\u5fae\u955c (23\u4e2a\u9879\u76ee)\">ASI\u5149\u7247\u7167\u660e\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e5%85%89%e7%89%87%e8%8d%a7%e5%85%89%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-3 tag-link-position-4\" style=\"font-size: 22pt;\" aria-label=\"ASI\u5149\u7247\u8367\u5149\u663e\u5fae\u955c (27\u4e2a\u9879\u76ee)\">ASI\u5149\u7247\u8367\u5149\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e6%98%be%e5%be%ae%e9%95%9c%e4%bd%8d%e7%a7%bb%e5%8f%b0\/\" class=\"tag-cloud-link tag-link-4 tag-link-position-5\" style=\"font-size: 19.573333333333pt;\" aria-label=\"ASI\u663e\u5fae\u955c\u4f4d\u79fb\u53f0 (20\u4e2a\u9879\u76ee)\">ASI\u663e\u5fae\u955c\u4f4d\u79fb\u53f0<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e6%98%be%e5%be%ae%e9%95%9c%e4%bd%8d%e7%a7%bb%e5%b9%b3%e5%8f%b0\/\" class=\"tag-cloud-link tag-link-5 tag-link-position-6\" style=\"font-size: 19.2pt;\" aria-label=\"ASI\u663e\u5fae\u955c\u4f4d\u79fb\u5e73\u53f0 (19\u4e2a\u9879\u76ee)\">ASI\u663e\u5fae\u955c\u4f4d\u79fb\u5e73\u53f0<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e6%98%be%e5%be%ae%e9%95%9c%e6%bb%91%e8%bd%a8\/\" class=\"tag-cloud-link tag-link-6 tag-link-position-7\" style=\"font-size: 18.453333333333pt;\" aria-label=\"ASI\u663e\u5fae\u955c\u6ed1\u8f68 (17\u4e2a\u9879\u76ee)\">ASI\u663e\u5fae\u955c\u6ed1\u8f68<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/ls-25%e7%ba%bf%e6%80%a7%e6%bb%91%e8%bd%a8\/\" class=\"tag-cloud-link tag-link-7 tag-link-position-8\" style=\"font-size: 18.453333333333pt;\" aria-label=\"LS-25\u7ebf\u6027\u6ed1\u8f68 (17\u4e2a\u9879\u76ee)\">LS-25\u7ebf\u6027\u6ed1\u8f68<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/ls-50%e7%94%b5%e6%8e%a7%e7%ba%bf%e6%80%a7%e4%bd%8d%e7%a7%bb%e5%b9%b3%e5%8f%b0\/\" class=\"tag-cloud-link tag-link-8 tag-link-position-9\" style=\"font-size: 18.453333333333pt;\" aria-label=\"LS-50\u7535\u63a7\u7ebf\u6027\u4f4d\u79fb\u5e73\u53f0 (17\u4e2a\u9879\u76ee)\">LS-50\u7535\u63a7\u7ebf\u6027\u4f4d\u79fb\u5e73\u53f0<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e7%be%8e%e5%9b%bdasi%e6%b5%b8%e6%b2%a1%e5%bc%8f%e7%89%a9%e9%95%9c\/\" class=\"tag-cloud-link tag-link-9 tag-link-position-10\" style=\"font-size: 18.453333333333pt;\" aria-label=\"\u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c (17\u4e2a\u9879\u76ee)\">\u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>\u4ee3\u7406Applied Scientific Instrumentation ASI LS-400\u7535\u63a7\u7ebf\u6027\u4f4d\u79fb\u5e73\u53f0 Applied Scientific Instrumentation <\/p>\n","protected":false},"author":29,"featured_media":192,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[1],"tags":[38,57,20,4,33,39,40,37,36,22],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts\/220"}],"collection":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/users\/29"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/comments?post=220"}],"version-history":[{"count":1,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts\/220\/revisions"}],"predecessor-version":[{"id":221,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts\/220\/revisions\/221"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/media\/192"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/media?parent=220"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/categories?post=220"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/tags?post=220"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}