﻿{"id":154,"date":"2025-09-24T17:24:51","date_gmt":"2025-09-24T09:24:51","guid":{"rendered":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/?p=154"},"modified":"2025-09-28T17:24:43","modified_gmt":"2025-09-28T09:24:43","slug":"%e7%be%8e%e5%9b%bdasi%e6%b5%b8%e6%b2%a1%e5%bc%8f%e7%89%a9%e9%95%9c%e6%98%be%e5%be%ae%e9%95%9c%e7%89%a9%e9%95%9c%e6%b5%b8%e6%b2%b9%e7%89%a9%e9%95%9c%e7%89%a9%e9%95%9c%e8%b0%83%e7%84%a6%e9%95%9c","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/%e7%be%8e%e5%9b%bdasi%e6%b5%b8%e6%b2%a1%e5%bc%8f%e7%89%a9%e9%95%9c%e6%98%be%e5%be%ae%e9%95%9c%e7%89%a9%e9%95%9c%e6%b5%b8%e6%b2%b9%e7%89%a9%e9%95%9c%e7%89%a9%e9%95%9c%e8%b0%83%e7%84%a6%e9%95%9c\/","title":{"rendered":"\u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c,\u663e\u5fae\u955c\u7269\u955c,\u6d78\u6cb9\u7269\u955c,\u7269\u955c\u8c03\u7126\u955c\u5934,Applied Scientific Instrumentation\u5149\u7247\u7167\u660e\u663e\u5fae\u955c"},"content":{"rendered":"<h3><a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e7%be%8e%e5%9b%bdasi%e6%b5%b8%e6%b2%a1%e5%bc%8f%e7%89%a9%e9%95%9c\/\" title=\"View all posts in \u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c\" target=\"_blank\">\u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c<\/a>,<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e6%98%be%e5%be%ae%e9%95%9c%e7%89%a9%e9%95%9c\/\" title=\"View all posts in \u663e\u5fae\u955c\u7269\u955c\" target=\"_blank\">\u663e\u5fae\u955c\u7269\u955c<\/a>,<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e6%b5%b8%e6%b2%b9%e7%89%a9%e9%95%9c\/\" title=\"View all posts in \u6d78\u6cb9\u7269\u955c\" target=\"_blank\">\u6d78\u6cb9\u7269\u955c<\/a>,<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e7%89%a9%e9%95%9c%e8%b0%83%e7%84%a6%e9%95%9c%e5%a4%b4\/\" title=\"View all posts in \u7269\u955c\u8c03\u7126\u955c\u5934\" target=\"_blank\">\u7269\u955c\u8c03\u7126\u955c\u5934<\/a> <a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/applied-scientific-instrumentation\/\" title=\"View all posts in Applied Scientific Instrumentation\" target=\"_blank\">Applied Scientific Instrumentation<\/a>\u5149\u7247\u7167\u660e\u663e\u5fae\u955c<\/h3>\n<p>ASI\u548cSpecial Optics\u5f00\u53d1\u4e86\u4e24\u79cd\u503e\u659c\u7269\u955c\uff0c\u7528\u4e8e\u5bf9\u6e05\u9664\u7684\u7ec4\u7ec7\u6837\u672c\u8fdb\u884c<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e5%85%89%e7%89%87%e6%98%be%e5%be%ae%e9%95%9c\/\" title=\"View all posts in \u5149\u7247\u663e\u5fae\u955c\" target=\"_blank\">\u5149\u7247\u663e\u5fae\u955c<\/a>\u68c0\u67e5\uff0c\u5305\u62ecASI\u7684ct dSPIM\u3002\u7531\u4e8e\u72ec\u7279\u7684\u5f2f\u66f2\u7b2c\u4e00\u8868\u9762\uff0c\u8fd9\u4e9b\u7269\u955c\u5728\u6ca1\u6709\u6821\u6b63\u5957\u73af\u7684\u4efb\u4f55\u6298\u5c04\u7387\u4ecb\u8d28\u4e2d\u5de5\u4f5c\u3002\u5b83\u4eec\u5bf9\u4e8e\u6d78\u6ce1\u5728\u5305\u62ecDBE\u548cBABB\u5728\u5185\u7684\u82db\u523b\u4ecb\u8d28\u4e2d\u662f\u7a33\u5065\u7684<\/p>\n<div class=\"entry-preview\">\n<div id=\"preview\" class=\"entry-img\">\n<div id=\"pg-img\" class=\"jqzoom product-img\">\n<div id=\"uArS1bN6LjSdPwH429vksR5Lbiv5hm\" class=\"paragraph\">Applied Scientific Instrumentation\u53cc\u9009\u62e9\u6027\u5149\u7247\u7167\u660e\u663e\u5fae\u955cCt-dSPIM\u662f\u4e13\u4e1a\u4e3a\u6e05\u9664\u7684\u7ec4\u7ec7\u6837\u672c\u6210\u50cf\u8bbe\u8ba1\u7684\u53cc\u89c6\u56fe\u9009\u62e9\u6027\u5149\u7247<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e6%98%be%e5%be%ae%e9%95%9cspim\/\" title=\"View all posts in \u663e\u5fae\u955cSPIM\" target=\"_blank\">\u663e\u5fae\u955cSPIM<\/a>,\u9002\u5408\u5927\u5c3a\u5bf8\u6837\u54c1\u6210\u50cf,\u5e94\u7528\u4e8e\u5404\u79cd\u6e05\u9664\u7ec4\u7ec7\u6837\u672c\u6210\u50cf\uff0c\u5305\u62ec\u6574\u4e2a\u5c0f\u9f20\u5927\u8111\u548c\u5207\u7247\u7684\u6e05\u9664\u7ec4\u7ec7\u6210\u50cf\u3002<\/div>\n<div id=\"RkZGzI17OJkcHVyl0igMsiOMVU7ICP\" class=\"paragraph\"><\/div>\n<p><strong>\u00a0Applied Scientific Instrumentation\u00a0<\/strong> ASI\u6d78\u6ca1\u5f0f\u7269\u955c,\u663e\u5fae\u955c\u7269\u955c<strong>\u53c2\u6570<\/strong><\/p>\n<div class=\"main_color container_wrap_first container_wrap fullsize\">\n<div class=\"container av-section-cont-open\">\n<div class=\"post-entry post-entry-type-page post-entry-5810\">\n<div class=\"entry-content-wrapper clearfix\">\n<div class=\"flex_column av-qwit3m-2c4902bb13a72c3d945204ad3ff91698 av_two_third  avia-builder-el-6  el_after_av_one_third  el_before_av_section  avia-builder-el-last  flex_column_div av-zero-column-padding  column-top-margin\">\n<div class=\"tabcontainer av-o2bboi-65d89bd7dc4b1b5d6226a5728db2b628 top_tab  avia-builder-el-8  el_after_av_heading  avia-builder-el-last \" role=\"tablist\">\n<section class=\"av_tab_section av_tab_section av-3icqhe-dd698f466417e3bdf3fb06a1ef76a00b\">\n<div id=\"tab-id-2-content\" class=\"tab_content active_tab_content\" aria-hidden=\"false\">\n<div class=\"tab_inner_content invers-color\">\n<table border=\"1\" width=\"800\">\n<tbody>\n<tr>\n<td><strong>Specifications<\/strong><\/td>\n<td><strong>57-12-19<\/strong><\/td>\n<td><strong>54-10-12<\/strong><\/td>\n<td><strong>54-12-8<\/strong><\/td>\n<td><strong>Comments<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Numerical Aperture<\/td>\n<td>0.30 @ RI 1.53<\/td>\n<td>0.40 @ RI 1.45<\/td>\n<td>0.70 @ RI 1.45<\/td>\n<td>NA proportional to RI<\/td>\n<\/tr>\n<tr>\n<td>Immersion Media RI<\/td>\n<td>1.33 \u2013 1.56<\/td>\n<td>1.33 \u2013 1.56<\/td>\n<td>1.33- 1.56<\/td>\n<td>Includes all major clearing solutions<\/td>\n<\/tr>\n<tr>\n<td>Effective Focal Length<\/td>\n<td>19.6 mm @ RI 1.53<\/td>\n<td>12.0 mm @ RI 1.45<\/td>\n<td>8.4 mm @ RI 1.45<\/td>\n<td>Magnification proportional to RI<\/td>\n<\/tr>\n<tr>\n<td>Working Distance<\/td>\n<td>18.1 mm (for all RI)<\/td>\n<td>12 mm (for all RI)<\/td>\n<td>10.0 mm (for all RI)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Flat Sample Depth<\/td>\n<td>8.2 mm<\/td>\n<td>5.1 mm<\/td>\n<td>2.0 mm<\/td>\n<td>Imaging depth into flat sample at 45 degree tilt<\/td>\n<\/tr>\n<tr>\n<td>Field of View<\/td>\n<td>3.0 mm \u00d8<\/td>\n<td>1.2 mm \u00d8<\/td>\n<td>1.0 mm \u00d8<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Spherical Correction<\/td>\n<td>480 \u2013 900 nm<\/td>\n<td>480 \u2013 1000 nm<\/td>\n<td>480 \u2013 1300 nm<\/td>\n<td>Diffraction-limited for most media and \u03bb<\/td>\n<\/tr>\n<tr>\n<td>Chromatic Correction<\/td>\n<td>480 \u2013 720 nm<\/td>\n<td>480 \u2013 720 nm<\/td>\n<td>480 \u2013 720 nm<\/td>\n<td>Performance varies by media, optimized for CLARITY and TDE<\/td>\n<\/tr>\n<tr>\n<td>Correction Collar<\/td>\n<td>None<\/td>\n<td>None<\/td>\n<td>None<\/td>\n<td>Designed for immersion w\/o coverslip<\/td>\n<\/tr>\n<tr>\n<td>Parfocal Length<\/td>\n<td>75.0 mm<\/td>\n<td>61.6 mm<\/td>\n<td>83 mm<\/td>\n<td>Both have M25 threads<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"av_tab_section av_tab_section av-32fthe-6541b5701f976a990396e98fbaa78420\">\n<div id=\"tab-id-3-content\" class=\"tab_content\" aria-hidden=\"true\">\n<div class=\"tab_inner_content invers-color\">\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"av_tab_section av_tab_section av-34ru6a-07f2862bdb467c76c17fef67747fc4ee\">\n<div id=\"tab-id-4-content\" class=\"tab_content\" aria-hidden=\"true\">\n<div class=\"tab_inner_content invers-color\">\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<br><div class=\"tagcloud\"><a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/4d%e8%8d%a7%e5%85%89%e6%88%90%e5%83%8f\/\" class=\"tag-cloud-link tag-link-0 tag-link-position-1\" style=\"font-size: 18.652173913043pt;\" aria-label=\"4D\u8367\u5149\u6210\u50cf (19\u4e2a\u9879\u76ee)\">4D\u8367\u5149\u6210\u50cf<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/applied-scientific-instrumentation\/\" class=\"tag-cloud-link tag-link-1 tag-link-position-2\" style=\"font-size: 22pt;\" aria-label=\"Applied Scientific Instrumentation (32\u4e2a\u9879\u76ee)\">Applied Scientific Instrumentation<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-cb1\/\" class=\"tag-cloud-link tag-link-2 tag-link-position-3\" style=\"font-size: 11.804347826087pt;\" aria-label=\"ASI CB1 (6\u4e2a\u9879\u76ee)\">ASI CB1<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-cb1%e5%8d%95%e7%89%a9%e9%95%9c%e5%85%89%e7%89%87%e6%88%90%e5%83%8f%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-3 tag-link-position-4\" style=\"font-size: 11.804347826087pt;\" aria-label=\"ASI CB1\u5355\u7269\u955c\u5149\u7247\u6210\u50cf\u663e\u5fae\u955c (6\u4e2a\u9879\u76ee)\">ASI CB1\u5355\u7269\u955c\u5149\u7247\u6210\u50cf\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-ct-dspim\/\" class=\"tag-cloud-link tag-link-4 tag-link-position-5\" style=\"font-size: 8pt;\" aria-label=\"ASI Ct-dSPIM (3\u4e2a\u9879\u76ee)\">ASI Ct-dSPIM<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-dispim%e5%8f%8c%e4%be%a7%e5%80%92%e7%bd%ae%e9%80%89%e6%8b%a9%e5%b9%b3%e9%9d%a2%e7%85%a7%e6%98%8e%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-5 tag-link-position-6\" style=\"font-size: 13.326086956522pt;\" aria-label=\"ASI diSPIM\u53cc\u4fa7\u5012\u7f6e\u9009\u62e9\u5e73\u9762\u7167\u660e\u663e\u5fae\u955c (8\u4e2a\u9879\u76ee)\">ASI diSPIM\u53cc\u4fa7\u5012\u7f6e\u9009\u62e9\u5e73\u9762\u7167\u660e\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-imaging%e5%85%89%e7%89%87%e7%85%a7%e6%98%8e%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-6 tag-link-position-7\" style=\"font-size: 17.586956521739pt;\" aria-label=\"ASI imaging\u5149\u7247\u7167\u660e\u663e\u5fae\u955c (16\u4e2a\u9879\u76ee)\">ASI imaging\u5149\u7247\u7167\u660e\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi-leica\/\" class=\"tag-cloud-link tag-link-7 tag-link-position-8\" style=\"font-size: 16.826086956522pt;\" aria-label=\"ASI Leica (14\u4e2a\u9879\u76ee)\">ASI Leica<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e5%85%89%e7%89%87%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-8 tag-link-position-9\" style=\"font-size: 20.173913043478pt;\" aria-label=\"ASI\u5149\u7247\u663e\u5fae\u955c (24\u4e2a\u9879\u76ee)\">ASI\u5149\u7247\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e5%85%89%e7%89%87%e7%85%a7%e6%98%8e%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-9 tag-link-position-10\" style=\"font-size: 19.869565217391pt;\" aria-label=\"ASI\u5149\u7247\u7167\u660e\u663e\u5fae\u955c (23\u4e2a\u9879\u76ee)\">ASI\u5149\u7247\u7167\u660e\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e5%85%89%e7%89%87%e8%8d%a7%e5%85%89%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-10 tag-link-position-11\" style=\"font-size: 20.934782608696pt;\" aria-label=\"ASI\u5149\u7247\u8367\u5149\u663e\u5fae\u955c (27\u4e2a\u9879\u76ee)\">ASI\u5149\u7247\u8367\u5149\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/asi%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-11 tag-link-position-12\" style=\"font-size: 21.391304347826pt;\" aria-label=\"ASI\u663e\u5fae\u955c (29\u4e2a\u9879\u76ee)\">ASI\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/ispim%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-12 tag-link-position-13\" style=\"font-size: 18.652173913043pt;\" aria-label=\"iSPIM\u663e\u5fae\u955c (19\u4e2a\u9879\u76ee)\">iSPIM\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/sols%e5%8d%95%e7%89%a9%e9%95%9c%e5%85%89%e7%89%87%e6%88%90%e5%83%8f%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-13 tag-link-position-14\" style=\"font-size: 19.869565217391pt;\" aria-label=\"SOLS\u5355\u7269\u955c\u5149\u7247\u6210\u50cf\u663e\u5fae\u955c (23\u4e2a\u9879\u76ee)\">SOLS\u5355\u7269\u955c\u5149\u7247\u6210\u50cf\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/spim%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-14 tag-link-position-15\" style=\"font-size: 18.652173913043pt;\" aria-label=\"SPIM\u663e\u5fae\u955c (19\u4e2a\u9879\u76ee)\">SPIM\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e5%85%89%e7%89%87%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-15 tag-link-position-16\" style=\"font-size: 18.95652173913pt;\" aria-label=\"\u5149\u7247\u663e\u5fae\u955c (20\u4e2a\u9879\u76ee)\">\u5149\u7247\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e5%8d%95%e7%89%a9%e9%95%9c%e5%85%89%e7%89%87%e6%88%90%e5%83%8f%e6%98%be%e5%be%ae%e9%95%9c\/\" class=\"tag-cloud-link tag-link-16 tag-link-position-17\" style=\"font-size: 19.260869565217pt;\" aria-label=\"\u5355\u7269\u955c\u5149\u7247\u6210\u50cf\u663e\u5fae\u955c (21\u4e2a\u9879\u76ee)\">\u5355\u7269\u955c\u5149\u7247\u6210\u50cf\u663e\u5fae\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e6%98%be%e5%be%ae%e9%95%9cspim\/\" class=\"tag-cloud-link tag-link-17 tag-link-position-18\" style=\"font-size: 18.347826086957pt;\" aria-label=\"\u663e\u5fae\u955cSPIM (18\u4e2a\u9879\u76ee)\">\u663e\u5fae\u955cSPIM<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e6%98%be%e5%be%ae%e9%95%9c%e7%89%a9%e9%95%9c\/\" class=\"tag-cloud-link tag-link-18 tag-link-position-19\" style=\"font-size: 18.04347826087pt;\" aria-label=\"\u663e\u5fae\u955c\u7269\u955c (17\u4e2a\u9879\u76ee)\">\u663e\u5fae\u955c\u7269\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e6%b5%b8%e6%b2%b9%e7%89%a9%e9%95%9c\/\" class=\"tag-cloud-link tag-link-19 tag-link-position-20\" style=\"font-size: 17.130434782609pt;\" aria-label=\"\u6d78\u6cb9\u7269\u955c (15\u4e2a\u9879\u76ee)\">\u6d78\u6cb9\u7269\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e7%89%a9%e9%95%9c%e8%b0%83%e7%84%a6%e9%95%9c%e5%a4%b4\/\" class=\"tag-cloud-link tag-link-20 tag-link-position-21\" style=\"font-size: 17.130434782609pt;\" aria-label=\"\u7269\u955c\u8c03\u7126\u955c\u5934 (15\u4e2a\u9879\u76ee)\">\u7269\u955c\u8c03\u7126\u955c\u5934<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e7%be%8e%e5%9b%bdasi%e6%b5%b8%e6%b2%a1%e5%bc%8f%e7%89%a9%e9%95%9c\/\" class=\"tag-cloud-link tag-link-21 tag-link-position-22\" style=\"font-size: 18.04347826087pt;\" aria-label=\"\u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c (17\u4e2a\u9879\u76ee)\">\u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c<\/a>\n<a href=\"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/tag\/%e9%ab%98%e5%88%86%e8%be%a8%e7%8e%87%e5%85%89%e7%89%87%e6%88%90%e5%83%8f%e7%b3%bb%e7%bb%9f\/\" class=\"tag-cloud-link tag-link-22 tag-link-position-23\" style=\"font-size: 18.652173913043pt;\" aria-label=\"\u9ad8\u5206\u8fa8\u7387\u5149\u7247\u6210\u50cf\u7cfb\u7edf (19\u4e2a\u9879\u76ee)\">\u9ad8\u5206\u8fa8\u7387\u5149\u7247\u6210\u50cf\u7cfb\u7edf<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>\u7f8e\u56fdASI\u6d78\u6ca1\u5f0f\u7269\u955c,\u663e\u5fae\u955c\u7269\u955c,\u6d78\u6cb9\u7269\u955c,\u7269\u955c\u8c03\u7126\u955c\u5934 Applied Scientific Instrumentation\u5149\u7247\u7167\u660e\u663e\u5fae\u955c ASI\u548cSpecial Optics\u5f00 <\/p>\n","protected":false},"author":29,"featured_media":155,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[1],"tags":[11,3,7,10,21,13,17,5,18,20,4,6,14,8,16,15,9,19,23,24,25,22,12],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts\/154"}],"collection":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/users\/29"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":1,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts\/154\/revisions"}],"predecessor-version":[{"id":156,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/posts\/154\/revisions\/156"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/media\/155"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/media?parent=154"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/categories?post=154"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/applied-scientific-instrumentation\/wp-json\/wp\/v2\/tags?post=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}