adamczewski elektronische messtechnik-EX-COMPONENTS 防爆零部件 模拟标准信号 接触放大器

模拟标准信号

AD-STVEX 710 GVD

产品介绍

电源隔离放大器用于为安装在危险区域的变送器提供本质安全电源。电源隔离放大器本身作为相关电气设备安装在非危险区域(即安全区域)。信号被电隔离并传输到非危险区域。无源输入还允许来自危险区域的有源信号。有源电流输出、电流吸收输出和电压输出便于适应后续信号输入。该设备可在 24 V DC 或 230 V AC 下运行。

产品参数

Transmitter input, intrinsically safe
Feeding voltage23V @ 4mA … 16V @ 20mA
Maximum measuring range0 … 22 mA
Maximum short circuit current68 mA
Current input, intrinsically safe
Maximum measuring range0 … 22 mA
Input resistance50 Ohm
Current output, active
Maximum output range0 … 22 mA
Max. burden500 Ohm
Current sink output, passive
Maximum output range0 … 22 mA
Max. external supply voltage25 V DC
Max. burden(Uextern – 2V) / 20mA
Output voltage
Maximum output range0 … 11 V
Min. burden2 kOhm
Transmission behaviour
Resolution input~ 20 µA/LSB
Resolution current output~ 20 µA/LSB
Resolution voltage output~ 10 mV/LSB
Maximum error0,2 % of full scale
Temperature influence~ 50 ppm/K
Response time~ 100 ms (10 … 90 %)
Auxiliary voltage
Range20 … 120 V DC / 50 … 250 V AC
Power consumption1,8 W / 3,5 VA
Environmental conditions
Ambient temperature-20 … +60 °C
Approval
ATEXII (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
Type examination certificateBVS 11 ATEX E 013 X
StandardsEN 60079-0, EN 60079-11
EN 60079-26, EN 61241-11
EMC
Product family standardEN 61326-1
Emitted interferenceEN 55011, CISPR11 Kl. B, Gr. 1
Electrical safety requirements
Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2

 

接触放大器

AD-KVEX 100/200 GVD

产品介绍

接触放大器(开关放大器)优选地用于保护弱传感器接触或放大二进制传感器信号。 AD-KVEX 100/200 GVD 提供在触点输出处放大的逻辑输入信号。典型的输入信号是簧片触点、符合 Namur Namur (DIN EN 60947-5-6) 的信号传感器或电阻变化。在输出端,提供重载和无源触点。对于每个导管,逻辑切换方向以及线路故障识别是可单独切换的。 AD-KVEX 100/200 GVDO 版本具有无磨损半导体输出,也通过光学隔离进行电流隔离。该器件包含电子宽范围电源,可以在宽电源电压范围内运行。

产品参数

Signal input
Min. pulse width100 ms
Namur supply voltageCa. 8,2 V DC +/-3%
Logic level, Low< 1,6 mA
Logic level, High> 1,9 mA
Wire breakage detection< 0,2 mA
Short circuit detection> 7,8 mA
Signal typesInitiator DIN EN 60947-5-6, contact, transistor
Contact output
Maximum switching load AC250 V, 2 A
Maximum switching load DC50 V, 2 A
Contact constructionPotential-free changeover
Switching operations mechanical1 x 10 7
At 230V/2A AC, cos(phi)=16 x 10 5
At 230V/2A AC, cos(phi)=0,42 x 10 5
At 50V/2 A DC2 x 10 5
Semiconductor output
Max switching voltage30 V DC
Max. switching current50 mA DC
Supply
Voltage range AC50 … 250 V AC, 50/60 Hz
Nominal voltage AC230 V AC
Power consumption AC3,5 VA (2,3 VA ; KVEX 100 GVD)
Voltage range DC20 … 120 V DC
Nominal voltage DC24 V DC
Power consumption DC1,8 W (1W ; KVEX 100 GVD)
Transmission behaviour
Response time~ 100 ms
Housing
Dimensions (WxHxD)23 x 110 x 134 mm
Type of protectionIP 20
Connection methodDetachable terminal clamp
Terminals, wire cross section2,5 mm² flex wire / 4 mm² one wire
Bolting torque terminals0,5 Nm
Weight~ 115 g
Manner of fastening35 mm DIN rail 35mm (EN50022)
Environmental conditions
Ambient temperature-20 … +60 °C
Storage and transport-20 … +70 °C (no condensation)
Approval
ATEXII(1) G [Ex ia Ga] IIC
II(1) D [Ex ia Da] IIIC
EU-Type Examination CertificateBVS 16 ATEX E 038 X
Safety Specifications per channel
Voltage Uo9,56 V DC
Current Io10,62 mA DC
Power Po25,4 mW
Max. external capacitance Co
||C
||B |||C
||A
3,6 µF
26 µF
210 µF
Max. external inductance Lo
||C
||B |||C
||A
315 mH
1261 mH
2522 mH
Max. external inductance / resistance ratio Lo/Ro
||C
||B |||C
||A
1,41 mH/Ohm
5,65 mH/Ohm
11,3 mH/Ohm
Internal capacitance CiN/A
Internal inductance LiN/A
Safety Specifications 2 channels parallel
Voltage Uo9,56 V DC
Current Io21,24 mA DC
Power Po50,8 mW
Max. external capacitance Co
||C
||B |||C
||A
3,6 µF
26 µF
210 µF
Max. external inductance Lo
||C
||B |||C
||A
78,8 mH
315,25 mH
630,5 mH
Max. external inductance / resistance ratio Lo/Ro
||C
||B |||C
||A
0,706 mH/Ohm
2,826 mH/Ohm
5,565 mH/Ohm
Internal capacitance CiN/A
Internal inductance LiN/A
EMC
Product family standardEN 61326-1 1)
Emitted interferenceEN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2
Galvanic isolation, test voltages
Input / output3 kV, 50 Hz (1 min.)
Signal / supply unit3 kV, 50 Hz (1 min.)
Protection circuits
InputElectrical surge protection
Power supplyProtection against over voltage, over temperature and reverse polarity