The Bionetics Corporation, formerly Intek, Inc. 210R Rheotherm flow meter 流量计 210R-XDT-TUL1/16(1/4E)-4/20(S1)-220V-SW3-ISB
Description
210R-XDT-TUL1/16(1/4E)-4/20(S1)-220V-SW3-ISB
Consisting of flow sensing transducer, separate electronics package,
and interconnect cable
Flow Data
Fluid: Fermentation Liquor (See Note 1)
Customer Line Size: 6 mm
Customer Flow Range: 0.05-60 cc/min
Calibrated Flow Range A: 0.05-0.6 cc/min (See Note 2)
Calibrated Flow Range B: 0.3-6 cc/min
Calibrated Flow Range C: 3-60 cc/min
Switch point: 0.05 cc/min
Temperature-Max: 30 C - rated to 60 C
Temperature-Operating Range: -10 to 30 C
Pressure-Max: 2000 kPa
Pressure-Operating range: 0-2000 kPa
Viscosity: 0.17
Specific Gravity: 0.63857
Instrument Data
Transducer Type: TUL
Wetted Material: 316 SS (See Note 3)
Shell Material: PVC
Fittings: 1/4-inch tube stubs
Local Display: 2x16 character LCD with selectable Flow Rate,
Totalizer and Fluid Temperature
Calibration Units: cc/min
Output(s): 4 to 20 milliamp, and SPDT Relay
Input Power: 220 VAC 50 Hz
Electronics Enclosure: NEMA 7 - explosion proof
Cable Length: 10 ft; up to 200 ft. available at $3.00/ft.
Notes
1. Fluid - Intek may use a substitute calibration fluid while calibrating your instrument. If this is the case, a simple field
calibration adjustment will be necessary to guarantee the highest levels of accuracy.
2. Low End Capability – Historically we have not always been able to calibrate below 0.8 cc/min in our 1/16-inch
sensor but we will calibrate as close to 0.6 cc/min as is possible while still providing accurate measurements.
3. Wetted Material - The user is responsible for the selection of process-wetted materials in view of their corrosion
resistance. Intek, Inc. makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
4. User Interface Kit Model 210- USB adapter cable and UIS software will be included for switching between calibration channels.
5. Hazardous Environment - The flow sensor and electronics listed in item1 above are approved for use in Class I Div.
I Grps B, C, & D areas.
The Bionetics Corporation, formerly Intek, Inc. 210R Rheotherm flow meter 流量计 210R-XDT-TUL1/16(1/4E)-4/20(S1)-220V-SW3-ISB
询价采购The Bionetics Corporation, formerly Intek, Inc. 21
请微信扫描下方二维码或手动添加微信号2351992198>