PSL Systemtechnik GmbH Medium Pressure Test Facility P205-0003
⦁ Packaging of instrument and options/accessories on pallet with Shockwatch
Medium Pressure Test Facility Test set-up for "downstream" conditions
⦁ Max. pressure 200 bar (2900 psi), max. temperature 120 °C (248 °F)
⦁ Mid pressure light probe 200 bar (provided by customer from existing FT Measurement Site), FKM O-ring sealing
⦁ Pressure cell, inner volume approx. 450 ml, stainless steel (AISI 316 Ti), replacement body for low sample volume, PTFE
⦁ Special screwed head for easy closing / opening
⦁ Double-jacket vessel, thermal isolation
⦁ Ports for light probe, temperature sensor, titration inlet and outlet
⦁ Pressure sensor, Pt100 sensor adapter
⦁ Integrated magnetic stirrer, computer controlled
⦁ Inlet- / outlet fittings, tubes & adapters, valves, overpressure valve
⦁ According EC Pressure Equipment Directive 97/23/EG and German Standard for Pressure Systems AD2008
⦁ Max. pressure 200 bar (2900 psi), max. temperature 120 °C (248 °F)
⦁ Mid pressure light probe 200 bar (provided by customer from existing FT Measurement Site), FKM O-ring sealing
⦁ Pressure cell, inner volume approx. 450 ml, stainless steel (AISI 316 Ti), replacement body for low sample volume, PTFE
⦁ Special screwed head for easy closing / opening
⦁ Double-jacket vessel, thermal isolation
⦁ Ports for light probe, temperature sensor, titration inlet and outlet
⦁ Pressure sensor, Pt100 sensor adapter
⦁ Integrated magnetic stirrer, computer controlled
⦁ Inlet- / outlet fittings, tubes & adapters, valves, overpressure valve
⦁ According EC Pressure Equipment Directive 97/23/EG and German Standard for Pressure Systems AD2008
Additional items for operation
⦁ Mid Pressure Pump (P204-0003 WR)
⦁ Circulation Thermostat FT (P203-0064 230/50 or P203-0065 115/60)
⦁ Spare Parts (P512-0002) - optional
⦁ Mid Pressure Pump (P204-0003 WR)
⦁ Circulation Thermostat FT (P203-0064 230/50 or P203-0065 115/60)
⦁ Spare Parts (P512-0002) - optional
⦁ Low volume test loop for analysis of wax deposit, paraffin crystallization and emulsions in pipelines and tubing ⦁ For shear dependent screening of wax inhibitors, wax dissolvers and pour point depressants / viscosity improvers and emulsions ⦁ Fully automated by computer run, manual and automatic test runs, temperature ramps, shear ramps, step-size and closed cycle ramps etc., user-defined test lengths ⦁ Real-time charts display raw data of dynamic process for rapidly growing deposits (non-filtered) and Fully automated flow loop for the analysis of flow related properties:
⦁ Low volume test loop for analysis of wax deposit, paraffin crystallization and emulsions in pipelines and tubing ⦁ For shear dependent screening of wax inhibitors, wax dissolvers and pour point depressants / viscosity improvers and emulsions ⦁ Fully automated by computer run, manual and automatic test runs, temperature ramps, shear ramps, step-size and closed cycle ramps etc., user-defined test lengths ⦁ Real-time charts display raw data of dynamic process for rapidly growing deposits (non-filtered) and
PSL Systemtechnik GmbH Medium Pressure Test Facility P205-0003
询价采购PSL Systemtechnik GmbH Medium Pressure Test Facili
请微信扫描下方二维码或手动添加微信号2351992198>