The Bionetics Corporation, formerly Intek, Inc. 210R-X-TU3/16(SS)(1"#150RF)-4/20-120V-ISB 液体流量计 210R-X-TU3/16(SS)(1-150RF)-4/20-120V-ISB
Consisting of flow sensing transducer with separate electronics package and interconnect cable
Intek Model 210R represents our current technology and replaced the Model 200 Similar to S/N:03077-1
Flow Data
Fluid: Phosphoric acid (70%)
Customer Line Size: 1-inch pipe
Customer Flow Range: 3 - 30 lbs/hr
Calibrated Flow Range: 3 - 30 lbs/hr
Temperature - Max Requirement: 110 F
Temperature - Operating Range: 20 - 100 F
Pressure - Max Requirement: 150 PSIG
Pressure - Operating Range: 150 PSIG
Fluid Viscosity: 100 cp
Fluid Density: 1600 kg/m^3
Instrument Data
Transducer Type: Straight tube
Wetted Material: SS316 (see Note 2)
Shell Material: SS
Process Connection: ASME B16.5 Raised Face Flange #150: 1"
Local Display: Blind
Calibration Units: lbs/hr.
Outputs: Flow 4/20mA isolated
Input Power: 120VAC
Electronics Enclosure: NEMA 7 10x14x6 blind, a flame proof enclosure, approved for IECEX EXd IIB IP66 areas.
Cable Length: 10 ft; (付费可升级至200 ft)
The Bionetics Corporation, formerly Intek, Inc. 210R-X-TU3/16(SS)(1"#150RF)-4/20-120V-ISB 液体流量计 210R-X-TU3/16(SS)(1-150RF)-4/20-120V-ISB
询价采购The Bionetics Corporation, formerly Intek, Inc. 21
请微信扫描下方二维码或手动添加微信号2351992198>