The Bionetics Corporation, formerly Intek, Inc. 210R-IDT-NPT/2I-4/20-220V 流量计
Consisting of flow sensing transducer, separate electronics package, and interconnect cable
Flow Data
Fluid: Freon R-350 (See Note 1)
Customer Line Size: 150 mm I.D. (See Note 2)
Customer Flow Range: 40 kg/h
Calibrated Flow Range: 8-80 kg/hr
Temperature-Max: 20 C
Temperature-Operating Range: 16-20 C
Pressure-Max: 1000 Pa
Pressure-Operating range: 700-1000 Pa
Viscosity: TBD
Specific Gravity: TBD
Instrument Data
Transducer Type: Insertion Probe
Wetted Material: 316 SS (See Note 3)
Fittings: 1-inch male NPT
Local Display: 2x16 character LCD with Flow Rate,
Totalizer and Flow Rate
Calibration Units: kg/hr
Output(s): 4 to 20 milliamp
Input Power: 220 VAC 50 Hz
Electronics Enclosure: NEMA 4
Cable Length: 10 ft; up to 200 ft available at ¥30/ft
Special Features
Insertion Length: Dimension X on DWG 93091 (See Note 4)
Notes
1. Intek may use a substitute calibration fluid while calibrating your instrument. If this is the case, a simple field calibration
adjustment will be necessary to guarantee the highest levels of accuracy.
2. In order to provide accurate flow readings, Intek Inc. recommends 15 pipe diameters upstream and 10 pipe diameters
downstream of the flow meter installation location. If sufficient straight run is unavailable Intek recommends item 2on
page 2.
3. The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Intek, Inc.
makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the
application described above.
4. Insertion Length – Please Submit dimension X on attached DWG-93091 for order to be processed.
The Bionetics Corporation, formerly Intek, Inc. 210R-IDT-NPT/2I-4/20-220V 流量计
询价采购The Bionetics Corporation, formerly Intek, Inc. 21
请微信扫描下方二维码或手动添加微信号2351992198>