The Bionetics Corporation, formerly Intek, Inc. 210-XDT-TU1/8(SS)(1/4MNPT)-4/20-24V-FM 流量计
Consisting of flow sensing transducer with integrated electronics package
Flow Data
Fluid: Gasoline (see Note 1)
Customer Line Size: 2-5 mm
Customer Flow Range: 0.2 lph – 1 lph
Calibrated Flow Range: 0.2 lph – 1 lph
Temperature - Max Requirement: 25 C
Temperature - Operating Range: 15 - 25 C
Pressure - Max Requirement: 500 PSIA
Pressure - Operating Range: ≤ 2 bar
Fluid Viscosity: 1.3393 cp
Fluid Density: 737 kg/m^3
Instrument Data
Transducer Type: Straight tube
Wetted Material: SS316 (see Note 2)
Shell Material: SS
Process Connection: Welded ¼-inch male NPT
Local Display: Selectable: Flow Rate, Totalizer, and Temperature
Calibration Units: lph
Outputs: Flow 4/20mA isolated
Input Power: 24VDC
Electronics Enclosure: NEMA 4X
Notes
1. Fluid - Calibration will be performed on the actual fluid if it can be handled safely and is readily available or if it can be supplied by Buyer
2. Wetted Material - The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Intek, Inc. makes no
guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
3. Item 2 above is FM approved for use in Class I Div I Grps B, C, & D hazardous areas.