The Bionetics Corporation, formerly Intek, Inc. inline flow meter 氮气流量计 210-IDT-TUL1/4-4/20-24V
210-IDT-TUL1/4-4/20-24V
Consisting of flow sensing transducer, integrated electronics package,
and interface cable
Flow Data
Fluid: Nitrogen
Customer Line Size: DN 15
Customer Flow Range: 0.5 - 6 Nm^3/hr
Calibrated Flow Range: 0.5 - 6 Nm^3/hr
Temperature - Max Requirement: 140 F
Temperature - Operating Range: 68 - 86 F
Pressure - Max Requirement: 500 PSIG
Pressure - Operating Range: 5 PSIG
Fluid Viscosity: 0.017754 cp
Fluid Density: 1.5347 kg/m^3
Instrument Data
Transducer Type: Inline Loop tube
Wetted Material: SS316
Shell Material: PVC
Process Connection: ¼-inch tube stubs
Local Display: Selectable: Flow Rate, Totalizer, and Temperature
Calibration Units: Nm^3/hr_
Outputs: Flow 4/20mA isolated
Input Power: 24VDC
Electronics Enclosure: NEMA 4X – (1) connector
Cable Length: 10 ft
and interface cable
Flow Data
Fluid: Nitrogen
Customer Line Size: DN 15
Customer Flow Range: 0.5 - 6 Nm^3/hr
Calibrated Flow Range: 0.5 - 6 Nm^3/hr
Temperature - Max Requirement: 140 F
Temperature - Operating Range: 68 - 86 F
Pressure - Max Requirement: 500 PSIG
Pressure - Operating Range: 5 PSIG
Fluid Viscosity: 0.017754 cp
Fluid Density: 1.5347 kg/m^3
Instrument Data
Transducer Type: Inline Loop tube
Wetted Material: SS316
Shell Material: PVC
Process Connection: ¼-inch tube stubs
Local Display: Selectable: Flow Rate, Totalizer, and Temperature
Calibration Units: Nm^3/hr_
Outputs: Flow 4/20mA isolated
Input Power: 24VDC
Electronics Enclosure: NEMA 4X – (1) connector
Cable Length: 10 ft
DN15 PN16 flange 316 SS
The Bionetics Corporation, formerly Intek, Inc. inline flow meter 氮气流量计 210-IDT-TUL1/4-4/20-24V
询价采购The Bionetics Corporation, formerly Intek, Inc. in
请微信扫描下方二维码或手动添加微信号2351992198>