Elabo GmbH Elabo Extension module "Insulation resistance” F1-1A E02
for high voltage unit F1-1A; F1-1M
For this extension module the extension module F1-1A E01 (HV-DC) is required.
Technical Data Isolation test:
• Measuring range: 1, 10, 100 MOhm
• Test Voltage kV/DC: 0,2..3,0 / 0,3..6
Resolution/Measurement error:
• Resolution Resistance measurement:
10kOhm (1MOhm - Range)
100kOhm (10MOhm - Range)
1MOhm (100MOhm - Range)
• Error of Resistance display up to 999V: 1MOhm- Range: 3% of reading + 1 Digit