Winkler AG ATEX-heated analysis line 加热束线 WEX80203-230ZE016-080003T3
ATEX-heated analysis line for use in hazardous areas of zone 1/2 (gas) and zone 21/22 (dust);
system certified version with EX Type Examination Certificate
Operating voltage 230 VAC; Nominal Power 150 W/m (+10%/-5%);
Max. admissible operating temperature 200°C; Sensor 2 x Pt100 ATEX; Nominal diameter DN 16; Length 8,00 m;
Connecting cable with ferrules LL=2 m;
Outer diameter (OD) approx. 55/60 mm; Temperature class T3
Our specification:
Heated line according to the following structure:
PTFE hose DN16 (20x1 mm) with stainless steel braiding; antistatic Fittings on both sides stainless-steel tubes-stubs RSL OD20/LA25 mm; Mat. 1.4571;
PTFE insulated heating cable, moisture protected with protective braiding; 2 x EX-i-Pt100, 3-wire, installation 300 mm from E-connection
Thermal insulation with multilayer thermal fleece;
Protective cover: polyamide corrugated hose (PA12), antistatic; Electrical connection side and the opposite ending side with silicone caps, antistatic;
Power and sensor cables are brought out separated;
in Polyamide corrugated hose; with ferrule, without plug
EC-Type examination certificate:
TPS 09 ATEX 1 006 X
EX-identification:
Gas EX II 2G Ex e mb IIC T3 Gb
Dust EX II 2D Ex mb tb IIIC T200°C Db
-40°C <= Ta <= +85°C