The Bionetics Corporation, formerly Intek, Inc. 210-XDT-TU1/16(1/4E)(SS)(HP)(1/4"MNPT)-HART-24V-FM 流量计
Flow Data Fluid:
Item 1-Tag # 32115 - Mixture of Hexane and Siloxane (see Note 2)
Item 2-Tag # 32215 - Mixture of Hexane and Aluminum Ethyl
Item 3-Tag # 32424 - Mixture of Catalyst and White Oil
Customer Line Size: 1/4"
Customer Flow Range: Item 1&2B– 10-400 g/hr; Item 3 – 5-300 g/hr
Calibrated Flow Range: Item 1&2 – 10-400 g/hr; Item 3 – 5-300 g/hr(see Note 3)
Temperature -Max Requirement: 40 °C
Temperature -Operating Range: 20 - 30 °C
Pressure -Max Requirement: 5 MPa
Pressure -Operating Range: Item 1&2 – 3.5 MPa; Item 3 – 4.5 MPa
Instrument Data
Transducer Type: Straight tube
Wetted Material: SS316/316L (see Note 4)
Shell Material: Stainless steel
Process Connection: Item 1&2 – MNPT: 1/4"; Item 3 – MNPT: 1/8”
Local Display: Selectable: Flow Rate, Totalizer, and Temperature
Calibration Units: g/hr
Outputs: HART
Input Power: 24VDC
Electronics Enclosure: NEMA 4X