Höntzsch GmbH (Hontzsch/Hoentzsch) TA Di 16 GE 60 m/s /140/p16 ZG1b 热式风速流量计 B016/504
TA Di 16 GE 60 m/s /140/p16 ZG1b
Thermal flow sensor TA with thin-film sensor in design as
measuring tube with inside diameter 16 mm for measuring
standard flow rate
Measuring range : 0.15 ... 43 m³/h
corresponding v mean : 0.2 ... 60 m/s in air,
1 m 3 /h = 1.38 m/s
Working temperature range : -10 °C ... +140 °C
Maximum working pressure : up to 16 bar/ 1.6 MPa above
atmospheric
Sensor element : epoxy resin-coated thin-film sensor
Materials
which come into contact
with the medium : stainless steel, epoxy resin, glass
Installation length : total ≅ 480 mm:
2/3 input section, 1/3 output section
Tube/tube connection : tube EN ISO 1127 or DIN 2463.
On the inlet/outlet sides, tapered
Whitworth outside thread R ½"
DIN 2999 = ISO 7, part 1 and 2.
Requisite counter thread RP ½"
Fitting attitude : as required
Connection housing : L·W·H = 80·80·60 mm
for max. +50 °C
Type of protection : sensor IP68
connection housing IP65
with transducer integrated in the connection housing
Transducer U10a / 24 VDC
for measuring the standard flow velocity Nv and the standard
flow rate NV/t of air / gases
Output flow : 4 ... 20 mA, max. 400 Ω
Pulse output : quantity measurement
Interface RS232 : only for transducer configuration
using a PC
Power supply : 24 V DC ±5%
Power consumption : less than 5 W
Connection : 7 pole connector G0 070
Parameter set no. : 00211
Software : ___
Measuring Function*
Measurement of flow in clean and dry air.
⦁ Measurement range : up to 400 l/min (24 Nm 3 /h)
Temperature : approx. +20 °C
Pressure : slightly overpressure
Inside diameter of measuring tube Di 16 mm
Protective system ATEX is not required
* Parameter maybe partly assumed, please check carefully!
Höntzsch GmbH (Hontzsch/Hoentzsch) TA Di 16 GE 60 m/s /140/p16 ZG1b 热式风速流量计 B016/504
询价采购Höntzsch GmbH (Hontzsch/Hoentzsch) TA Di 16 GE 60
请微信扫描下方二维码或手动添加微信号2351992198>