The Bionetics Corporation, formerly Intek, Inc. 210R-I-TUL1/16(HC)(SS)(200F)(HP)(1/4MNPT)-RS485-24V-(ER) 气体流量计
Consisting of flow sensing transducer with separate electronics package and interconnect cable
Flow Data
Fluid: Nitrogen (see Note 1)
Customer Line Size: 1/16-inch
Customer Flow Range: 0-100 LPM
Calibrated Flow Range: 0.5 - 50 SLPM (see Note 2)
Temperature - Max Requirement: 80 C
Temperature - Operating Range: -40 to 80 C
Pressure - Max Requirement: 10200 PSIG
Pressure - Operating Range: 70 MPA (10152 PSIG)
Fluid Viscosity: 0.018402 cp
Fluid Density: 754.087 kg/m^3
Instrument Data
Transducer Type: Straight tube
Wetted Material: Hastelloy C-276 and 316 SS (see Note 3)
Shell Material: SS
Process Connection: 1/4-inch MNPT (316 SS)
Local Display: Blind
Calibration Units: SLPM
Outputs: Serial MODBUS RS-485
Input Power: 24VDC
Electronics Enclosure: NEMA 4 8x6x3.5 blind
and interconnect cable.Consisting of flow sensing transducer with separate electronics package
and interconnect cable.
The Bionetics Corporation, formerly Intek, Inc. 210R-I-TUL1/16(HC)(SS)(200F)(HP)(1/4MNPT)-RS485-24V-(ER) 气体流量计
询价采购The Bionetics Corporation, formerly Intek, Inc. 21
请微信扫描下方二维码或手动添加微信号2351992198>